The gallon number on the box is the least useful number on a water heater. A 50-gallon tank does not hand you 50 gallons of hot water — it hands you about 35 before the outlet cools off, and then whatever the burner or the elements can put back while you keep drawing. The number that decides whether the fourth shower runs cold is the first-hour rating: how much hot water the heater can deliver in one hour, starting full and hot. It is printed on the yellow EnergyGuide label of every tank sold in the US, and it splits hard by fuel — a 40-gallon gas tank typically delivers 67 gallons in the first hour, while a 50-gallon electric tank typically delivers 61. Gas reheats water much faster than electric elements, so the smaller gas tank out-delivers the bigger electric one. This water heater size calculator adds up your busiest hour with the AHRI worksheet — 20 gallons per shower, 2 per shave, 4 per shampoo, 14 per dishwasher load, 32 per washer load — and matches it to the smallest standard tank whose first-hour rating covers it, by fuel: gas, electric, or heat pump. It also sizes a tankless heater by flow and temperature rise — 4.0 GPM at a 70°F rise is 139,944 BTU/hr — and it prices all four types to run for a year at your rates, with the heat-pump payback worked out without the federal credit, because that credit ended on 31 December 2025. For the rest of the hot-water system, price the electricity with the electricity cost calculator, size the heating load with the BTU calculator and the heat pump size calculator, check the radiators with the radiator size calculator and the insulation with the insulation calculator, and if the new heater is part of a bigger job, price the room with the bathroom remodel cost calculator and the kitchen remodel cost calculator.

Quick answer: A 4-person, 2-bathroom household whose busiest hour is 3 showers, a shave, a shampoo and hand dishwashing needs 70 gallons in that hour (AHRI worksheet) — so buy a tank whose first-hour rating is at least 70. A 50-gallon gas tank (typical FHR 81) covers it; a 50-gallon electric tank (typical FHR 61) does not — the smallest electric that covers it is a 65-gallon heat pump tank (FHR 75). A tankless needs 4.0 GPM at a 70°F rise — 139,944 BTU/hr (41.0 kW) — for two showers running at once. Enter your own morning below for your exact size, the tank that covers it, and what each type costs to run.
Key takeaways
  • Size a tank water heater by its first-hour rating, not its gallons: the rating is the hot water it delivers in one busy hour, starting full and hot, and it is printed on the yellow EnergyGuide label. A 40-gallon gas tank (typical FHR 67) out-delivers a 50-gallon electric tank (typical FHR 61).
  • The AHRI worksheet is the primary method: 20 gallons per shower, 20 per bath, 2 per shave, 4 per hand/face wash, shampoo or hand dishwashing, 14 per dishwasher load, 5 per food prep, 32 per washer load. Three showers, a shave, a shampoo and hand dishwashing add to 70 gallons.
  • The DOE worksheet gives a smaller number for the same morning — 65 gallons — because it counts 7 gallons for a dishwasher load where AHRI counts 14, and 25 for a top-loader where AHRI counts 32. The two methods disagree by 5 gallons on one morning; the tool prints both and sizes from the larger.
  • The same 4-person, 2-bathroom household is 101 gallons by one online method, 78 by another, 70 by AHRI, 65 by DOE, 61 by a fixture-by-fixture method and 48 by a 60%-of-day method. That is a method spread, not an error — and the honest answer is the 80-gallon tank (or a 75-gallon gas) that covers the top of it.
  • A heat pump water heater costs about $194 a year to run against $738 for a standard electric tank at 68 gallons a day — but the federal 25C credit ended on 31 December 2025, so the payback is the installed-price premium divided by the saving, about 4.5 years at these rates, with no credit in it.
Full-time residents. Used for the household-size cross-check (Angi’s table) and for the default daily use — 17 gallons per person per day, the DOE average.
Used for the household-size cross-check only — the worksheet below counts what actually happens in the busiest hour, not how many bathrooms you have. A 2-bathroom home where everyone showers in the same hour still needs the worksheet number.
How many showers happen in the busiest single hour — usually the morning. AHRI counts about 20 gallons of hot water per shower (no water-saving fixtures assumed). Three showers alone are 60 gallons.
AHRI counts about 20 gallons per bath — the same as a shower. A tub fill is the single biggest draw in the worksheet, and two tubs in one hour is 40 gallons before anyone showers.
AHRI counts about 2 gallons per shave; the DOE worksheet counts the same 2 gallons. Small on its own, but it is in both worked examples — the DOE example is 3 showers, a shave and hand dishwashing.
AHRI counts about 4 gallons each. The DOE worksheet has no separate line for this — it folds hand washing into the 3-gallon hand dishwashing / food prep line, which is one reason the two worksheets disagree.
AHRI counts about 4 gallons each — a shampoo at the sink, not in the shower. The AHRI worked example is 3 showers, a shave, a shampoo and hand dishwashing: 60 + 2 + 4 + 4 = 70 gallons.
AHRI counts about 4 gallons each; the DOE worksheet counts 3 gallons for hand dishwashing or food prep. One of the two lines where the worksheets disagree — the other is the dishwasher.
AHRI counts 14 gallons per load; the DOE worksheet counts 7. That 7-gallon gap is the biggest single disagreement between the two worksheets — a morning with a dishwasher load is 65 gallons by DOE and 72 by AHRI on the default counts. Modern ENERGY STAR dishwashers use 3–6 gallons a cycle in reality.
AHRI counts about 5 gallons each; the DOE worksheet counts 3 gallons for hand dishwashing or food prep combined. Rarely the deciding line, but it is in the worksheet, so it is in the tool.
AHRI counts 32 gallons per load (warm cycle, no water-saving fixtures). The DOE worksheet counts 25 for a top-loader and 15 for a high-efficiency (H-axis) machine. A washer load in the peak hour is the second-biggest single draw after a bath — run it outside the shower hour and the tank can be a size smaller.
The fuel decides the recovery speed, and the recovery speed decides the first-hour rating. Gas reheats fastest, so a 40-gallon gas tank (FHR 67) out-delivers a 50-gallon electric tank (FHR 61). Standard electric tanks stop at 50 gallons — a bigger electric home steps up to a heat pump tank.
Groundwater temperature is the sizing swing for a tankless heater and the cost swing for every type. Winter water is about 40°F in the north (Boston groundwater is 47°F) and about 70°F in the south (Orlando is 72°F). The federal test uses 58°F in and 125°F out. Pick “Custom” and enter your own below.
Used only when the inlet above is “Custom”. Enter the coldest groundwater temperature your home sees — usually the January figure. Leave it blank unless you picked “Custom”.
The temperature the tank holds — 120°F is the usual recommendation (hot enough to shower, cool enough to limit scalding). 140°F needs a mixing valve at the tap, because 140°F water scalds in seconds. The temperature rise is this number minus the inlet temperature.
For the tankless size only — how many showers run simultaneously, not in the same hour. Two showers at once is the usual case for a 2-bathroom home; three at once needs a bigger unit or a second one.
The flow each shower actually draws. The federal maximum for a showerhead is 2.5 GPM; WaterSense heads are 2.0 or less. Two showers at 2.0 GPM need 4.0 GPM; at 2.5 GPM they need 5.0 GPM — and the BTU figure follows the flow.
Sinks and other small taps running at the same time as the showers — 0.5 GPM each. A sink left running while two people shower adds 0.5 GPM to the tankless size.
0.5 GPM while it fills. A dishwasher that fills during the morning showers adds half a gallon a minute to the tankless size — small, but it is the line that pushes a 4.0 GPM home to 4.5.
2.0 GPM while it fills. A washer filling during the showers is the biggest simultaneous extra after a third shower — it adds as much as a whole shower at 2.0 GPM.
Defaults to 17 gallons per person per day — the DOE average (50.6 gallons a day for the average household) — so 4 people is 68 gallons a day. Used only for the annual running cost, not for the size: size comes from the busiest hour, cost comes from the whole day. Change it if your household uses more or less.
Your residential electricity price. The default $0.16 per kWh is the national average used for the worked examples. The electric and heat-pump annual costs scale directly with this number.
Your natural gas price per therm (100,000 BTU). The default $1.50 per therm is the figure used for the worked examples. The gas tank and tankless annual costs scale directly with this number.
What a standard electric tank costs installed in your area. Default $1,450 is the middle of the national $900–$2,000 range (Angi, HomeGuide, Fixr). Used for the heat-pump payback.
What a standard gas tank costs installed. Default $2,100 is the middle of the national $1,200–$3,000 range. Used for the heat-pump payback against gas.
What a heat pump (hybrid) tank costs installed. Default $3,900 is the middle of the national $2,800–$5,000 range. The payback is this premium over the electric or gas tank, divided by the annual saving.
What a whole-house gas tankless costs installed. Default $4,050 is the middle of the $2,500–$5,600 range (HomeGuide); Angi’s figure for a new tankless install is $5,400–$7,400, which covers conversions that need a bigger gas line and new venting.

Planning this project? Save to Pinterest to find this calculator again later.

How to use the Water Heater Size Calculator — What Size Water Heater Do I Need?

  1. Count the people and the bathrooms. Full-time residents and bathrooms in the home. These feed the household-size cross-check (Angi’s table) and the default daily use — 17 gallons per person per day. They do not decide the size; the busiest hour does.
  2. Count what happens in the busiest hour. Go through the worksheet lines — showers, tub fills, shaves, hand and face washings, shampoos, hand dishwashing, dishwasher loads, food prep, washer loads — and enter how many times each happens in the single busiest hour, usually the morning. Three showers, a shave, a shampoo and hand dishwashing is the AHRI worked example: 70 gallons.
  3. Read the peak-hour demand. The tool adds the worksheet up two ways: the AHRI total (the headline) and the DOE total (the cross-check). On the defaults they are 70 and 65 gallons — the 5-gallon gap is the dishwasher (14 AHRI, 7 DOE) and the washer (32 AHRI, 25 DOE top-loader). The tool sizes from the AHRI figure, the larger of the two.
  4. Pick the fuel. Gas, electric or heat pump. The fuel decides the recovery speed, and the recovery speed decides the first-hour rating: a 40-gallon gas tank delivers about 67 gallons in the first hour, a 50-gallon electric about 61, a 50-gallon heat pump about 66. Standard electric tanks stop at 50 gallons.
  5. Read the tank that covers it. The tool picks the smallest standard tank whose typical first-hour rating is at least the peak-hour demand, for the fuel you picked. On the defaults — 70 gallons — that is a 50-gallon gas tank (FHR 81), a 65-gallon heat pump tank (FHR 75), and no standard electric tank at all (the biggest is 50 gallons, FHR 61).
  6. Check the household table. Angi’s table by household size is the quick cross-check: 4 people is 50–60 gallons of tank, 3–4 people is 8–10 GPM tankless. If the worksheet and the table disagree by a size, trust the worksheet — it counts your morning, and the table counts an average household.
  7. Set the inlet temperature. North winter 40°F, central 50°F, south 70°F — or your own number. This is the sizing swing for a tankless heater: the same 4.0 GPM needs 139,944 BTU/hr at a 70°F rise and only 99,960 BTU/hr at a 50°F rise. Cold water is why the north needs a bigger tankless.
  8. Set the setpoint. 120°F is the usual recommendation. The temperature rise is the setpoint minus the inlet — 70°F on the defaults — and every BTU and cost figure on the page follows that rise. 140°F needs a mixing valve, because 140°F water scalds in seconds.
  9. Read the tankless size. Enter the showers running at the same time and the flow per head, plus any taps, dishwasher or washer running with them. The tool gives the GPM, the BTU/hr (GPM × 8.33 × rise × 60) and the kW — 4.0 GPM at a 70°F rise is 139,944 BTU/hr, 41.0 kW. Compare that with the household table’s GPM band for your household size.
  10. Read the annual running cost. The tool heats your daily gallons at your temperature rise for a year, at your rates, for all four types: electric tank (UEF 0.92), gas tank (UEF 0.64), heat pump (UEF 3.5) and tankless gas (UEF 0.82). On the defaults — 68 gallons a day — that is $738, $339, $194 and $265 a year. The heat pump is the cheapest to run by a wide margin.
  11. Read the heat-pump payback. The installed-price premium over the electric or gas tank, divided by the annual saving. On the defaults the heat pump costs $2,450 more than the electric tank and saves $544 a year — about 4.5 years. There is no federal credit in that figure: the 25C credit ended on 31 December 2025.
  12. Take the size to a plumber. The size is the answer; the install is the plumber’s job. Gas-line capacity, venting, the electrical panel, water pressure, the space the tank fits in and local code are all outside this page — and the first-hour rating on the yellow label of the model you buy is the number that counts, not the table on this page.

Water Heater Size Calculator — What Size Water Heater Do I Need? formula

Peak-hour demand (AHRI worksheet): showers × 20 + baths × 20 + shaves × 2 + hand/face washings × 4 + shampoos × 4 + hand dishwashing × 4 + dishwasher loads × 14 + food prep × 5 + washer loads × 32 — all in gallons of hot water in the busiest hour. DOE worksheet (cross-check): showers × 20 + shaves × 2 + (hand dishwashing + food prep) × 3 + dishwasher loads × 7 + washer loads × 25 (top-loader; 15 for a high-efficiency machine). The DOE worksheet has no bath, hand/face or shampoo line, and it counts 7 gallons for a dishwasher load where AHRI counts 14 — so the same morning is 65 gallons by DOE and 70 by AHRI on the defaults.

First-hour rating (FHR): the gallons of hot water a tank can deliver in one hour, starting full and hot — FHR ≈ usable storage + one hour of recovery, where usable storage is about 70% of the tank (the rest cools below a useful temperature before it can be drawn) and recovery is the burner or elements’ output for an hour. The federal test (10 CFR 430, Appendix E) draws at 3.0 gpm with 58°F water in and 125°F out, and stops counting when the outlet drops 25°F. Buy a tank whose FHR is at least the peak-hour demand (DOE Building America: FHR ≥ peak). Recovery: gas ≈ 40,000 BTU/hr × 80% ÷ (8.33 × rise) — about 57 gph at the 67°F test rise; electric ≈ 4,500 W × 98% ÷ (8.33 × rise) — about 27 gph at the test rise.

Tankless flow: GPM = showers at once × flow per head + taps at once × 0.5 + dishwasher at once × 0.5 + washer at once × 2.0. BTU/hr = GPM × 8.33 × temperature rise × 60 — 8.33 lb is the weight of a gallon of water, so a gallon a minute heated by 1°F needs 8.33 × 60 = 500 BTU/hr per degree. kW = BTU/hr ÷ 3,412. A tankless is rated by the flow it can hold at a stated rise — a unit rated 7 GPM at a 35°F rise delivers only about 3.5 GPM at a 70°F rise.

Annual running cost: heat needed = daily gallons × 365 × 8.33 × temperature rise (BTU a year). Electric kWh = heat ÷ 3,412 ÷ UEF; gas therms = heat ÷ 100,000 ÷ UEF. UEFs used here: electric tank 0.92, gas tank 0.64, heat pump 3.5, tankless gas 0.82 — all inside the published typical ranges (electric 0.90–0.95, gas tank 0.60–0.70, gas tankless 0.82–0.99, heat pump 3.0–4.0). The UEF already includes standby loss, cycling loss and recovery efficiency, so no separate standby line is added.

Heat-pump payback: (installed price of the heat pump tank − installed price of the electric or gas tank) ÷ (annual cost of that tank − annual cost of the heat pump). No federal credit is included: the Section 25C credit for heat pump water heaters ended for installations completed after 31 December 2025 (One Big Beautiful Bill Act, P.L. 119-21).

Household rules of thumb (Angi): tank size ≈ 20 gallons base + 10 gallons per person; tankless ≈ 5 GPM base + 1 GPM per person. Daily use ≈ 17 gallons per person per day (DOE average, 50.6 gallons a day for the average household). Draw bands (10 CFR 430, Appendix E): very small FHR under 18 gallons, low 18 to under 51, medium 51 to under 75, high 75 and up — the band decides which daily draw pattern the heater is efficiency-tested on.

Metric: 1 US gallon = 3.78541 litres; 1 litre = 0.26417 gallons. °C = (°F − 32) × 5 ÷ 9 — so 120°F is 48.9°C, 140°F is 60°C, a 70°F rise is 38.9°C, and 40°F inlet water is 4.4°C. A 70-gallon peak hour is 265.0 litres; 68 gallons a day is 257.4 litres a day.

What this does not do: it does not check gas-line capacity, venting, the electrical panel, water pressure, recirculation, or the physical space; it does not model a heat pump’s slower recovery in a cold garage, a tankless unit’s minimum flow, or the cold-water sandwich; and the FHR table is typical label values — the rating on the model you buy is the number that counts.

Worked example

Worked example — the default morning: 4 people, 2 bathrooms, 3 showers, a shave, a shampoo and hand dishwashing in the busiest hour. This is the tool’s default, worked by hand so you can check it — and it is the field’s canonical comparison, because it is the morning where gas and electric give different answers.

  1. AHRI worksheet: 3 showers × 20 = 60, plus 1 shave × 2 = 2, plus 1 shampoo × 4 = 4, plus 1 hand dishwashing × 4 = 4 — 70 gallons in the busiest hour (265.0 litres). The DOE worksheet on the same morning: 3 showers × 20 = 60, plus 1 shave × 2 = 2, plus 1 hand dishwashing × 3 = 3 — 65 gallons (246.1 litres). DOE’s own page prints its example as 66 gallons; the rows it shows add to 65, a one-gallon slip that does not change the method. The 5-gallon gap is the dishwasher and washer lines, which are both zero here — the gap here is the hand-dishwashing line (4 AHRI, 3 DOE) and the shampoo line, which DOE does not count at all.
  2. First-hour rating needed: 70 gallons. Buy a tank whose FHR is at least 70 — that is the DOE Building America rule (FHR ≥ peak-hour demand), and it puts the household in the medium draw band (51 to under 75 gallons).
  3. Gas: the smallest standard gas tank that covers 70 is the 50-gallon (typical FHR 81). The 40-gallon gas tank (FHR 67) is 3 gallons short. Electric: no standard electric tank covers 70 — the biggest is the 50-gallon (FHR 61), 9 gallons short. Heat pump: the smallest that covers 70 is the 65-gallon (FHR 75); the 50-gallon heat pump (FHR 66) is 4 gallons short. So the same morning is a 50-gallon gas tank, a 65-gallon heat pump tank, or no electric tank at all.
  4. The DOE-65 version of the same morning (3 showers, a shave, hand dishwashing — the DOE worked example) is 65 gallons, and there the 40-gallon gas tank (FHR 67) covers it while the 50-gallon electric (FHR 61) does not. Two gallons of method difference move the gas answer one tank size — which is why the tool prints both worksheets instead of one number.
  5. Tankless: 2 showers at once at 2.0 gpm = 4.0 GPM. Temperature rise: 120°F setpoint minus 50°F inlet = 70°F. BTU/hr = 4.0 × 8.33 × 70 × 60 = 139,944 BTU/hr; kW = 139,944 ÷ 3,412 = 41.0 kW for an electric tankless. Angi’s household table puts 4 people at 9–11 GPM for a tankless — that band assumes more fixtures running at once than two showers, so read it as the whole-house figure and the 4.0 GPM as the two-shower figure.
  6. Annual running cost at 68 gallons a day (4 people × 17), a 70°F rise, $0.16/kWh and $1.50/therm. Heat needed: 68 × 365 × 8.33 × 70 = 14,472,542 BTU a year. Electric tank: 14,472,542 ÷ 3,412 ÷ 0.92 = 4,610 kWh × $0.16 = $738 a year. Gas tank: 144.7 therms ÷ 0.64 = 226 therms × $1.50 = $339 a year. Heat pump: 4,241 kWh ÷ 3.5 = 1,212 kWh × $0.16 = $194 a year. Tankless gas: 144.7 therms ÷ 0.82 = 176 therms × $1.50 = $265 a year.
  7. Heat-pump payback: the heat pump costs $3,900 installed against $1,450 for the electric tank — a $2,450 premium — and saves $738 − $194 = $544 a year. $2,450 ÷ $544 = about 4.5 years. Against the gas tank ($2,100 installed, $339 a year) the premium is $1,800 and the saving is $145 a year — about 12.4 years. No federal credit is in either figure: the 25C credit ended for installations completed after 31 December 2025.

Same household, six methods — the 48-to-101-gallon spread. For the same 4-person, 2-bathroom household, the published methods give: levelcalc 101 gallons (people × 12 + baths × 20 + dishwasher × 6 + washer × 7 = 48 + 40 + 6 + 7); septiwellguide 78 (10 × people + 12 × baths + 6 + 8 = 40 + 24 + 14); AHRI worksheet 70; DOE worksheet 65; gettheamount 61 (fixture-by-fixture, tank = peak ÷ 0.9); delimetra 48 (60% of the day’s use: 4 people × 20 gallons a day × 60%). That is a 2× spread for one household, and it is method, not error: the household-table methods count people and bathrooms, the worksheets count uses in the busiest hour, and the 60%-of-day method counts a share of the daily total. The honest answer is the tank that covers the top of the spread — an 80-gallon tank (heat pump FHR 87) or a 75-gallon gas tank (FHR 125) — not the tank that covers the average of it.

Delimetra check — 4 people, 80 gallons a day, electric. 4 people × 20 gallons = 80 gallons a day. Heat: 80 × 8.33 × 70 = 46,648 BTU a day = 13.67 kWh of heat; at UEF 0.92 that is 13.67 ÷ 0.92 = 14.9 kWh a day from the wall — the figure delimetra publishes, reproduced exactly.

Tankless at a colder rise — 2 showers, 3.2 GPM, 73°F rise. BTU/hr = 3.2 × 8.33 × 73 × 60 = 116,753 BTU/hr; kW = 116,753 ÷ 3,412 = 34.2 kW. That is the Boston case (47°F groundwater, 120°F setpoint): the same two showers need a bigger burner in the north than in the south, where a 50°F rise needs only 79,968 BTU/hr for the same 3.2 GPM.

Metric twin — 70 gallons is 265.0 litres. The AHRI peak of 70 gallons is 70 × 3.78541 = 265.0 litres; the DOE peak of 65 gallons is 246.1 litres; 68 gallons a day is 257.4 litres a day. A 70°F temperature rise is (70 × 5 ÷ 9) = 38.9°C. A 120°F setpoint is 48.9°C and 140°F is 60°C — the scalding line is the same in either unit.

Water heater sizing tables: the AHRI and DOE worksheets, first-hour ratings by fuel, household sizes, tankless flow, UEF, and the 48-to-101-gallon spread

First-hour rating is the spec, not tank volume. A tank’s first-hour rating is how much hot water it can deliver in one hour starting full and hot — usable storage (about 70% of the tank) plus one hour of recovery. The federal test draws at 3.0 gpm with 58°F water in and 125°F out, and stops counting when the outlet drops 25°F. That is why a 40-gallon gas tank (typical FHR 67) out-delivers a 50-gallon electric tank (typical FHR 61): the gas burner reheats at about 57 gallons an hour at the test rise, the electric elements at about 27. The rating is printed on the yellow EnergyGuide label as “Capacity (first hour rating)” — heat pump tanks do not carry that label, so check the spec sheet or the ENERGY STAR listing. Two tanks with the same gallon number can differ by 20 gallons in what they deliver in an hour: Rheem’s 40-gallon gas tanks run 64 to 84 gallons.

The AHRI worksheet (primary) and the DOE worksheet (cross-check) — and where they disagree. The tool sizes from AHRI and prints DOE beside it. The two disagreements are the dishwasher (14 AHRI, 7 DOE) and the washer (32 AHRI, 25 DOE top-loader, 15 DOE high-efficiency), plus the shampoo and hand/face lines, which DOE does not count separately. On a morning with a dishwasher load and a washer load, the gap is 7 + 7 = 14 gallons — enough to move the answer a tank size. Neither worksheet is wrong; they are different planning figures, and a calculator that prints one of them as “the” answer is hiding the spread.

The 48-to-101-gallon spread, with the methods named. For the same 4-person, 2-bathroom household: levelcalc 101 (people × 12 + baths × 20 + dishwasher × 6 + washer × 7); septiwellguide 78 (10 × people + 12 × baths + 6 + 8); AHRI worksheet 70; DOE worksheet 65; gettheamount 61 (fixture-by-fixture, then tank = peak ÷ 0.9); delimetra 48 (60% of the day’s 80 gallons). The household-table methods count people and bathrooms; the worksheets count uses in the busiest hour; the 60%-of-day method counts a share of the daily total. The tank that covers the top of the spread — an 80-gallon heat pump (FHR 87) or a 75-gallon gas tank (FHR 125) — is the conservative answer, and the page says so instead of picking the smallest number and calling it the answer.

Electric tanks stop at 50 gallons — and the 2029 rule makes it official. Standard electric resistance tanks are sold up to 50 gallons; a bigger electric home steps up to a heat pump tank (50, 65 or 80 gallons). Under the DOE’s newer rule, effective 6 May 2029, electric tanks over 35 gallons will need heat pump technology. The heat-pump upsizing angle is the differentiator no rival prints: a 65-gallon heat pump tank (FHR 75) is the smallest electric-family tank that covers a 70-gallon peak, and the ENERGY STAR NextGen minimum is 59 gallons for a 2–2.5-bathroom, 3-bedroom home.

The 25C credit is gone — do not put it in a payback. The federal Section 25C credit for heat pump water heaters ($600) was terminated by the One Big Beautiful Bill Act (P.L. 119-21, signed 4 July 2025) for installations completed after 31 December 2025. Several guides still quote the credit — one still quotes $2,000 — and any payback that includes it is overstated by that amount. This page’s payback is the installed-price premium divided by the annual saving, with no credit in it: about 4.5 years against an electric tank at these rates, about 12.4 years against gas.

Inlet temperature is the sizing swing. Winter groundwater is about 40°F in the north and about 70°F in the south (Boston 47°F, Orlando 72°F, per Angi; Ruud’s figures are 40°F north, 50°F south, 60°F Southwest and Gulf). A tankless heater’s BTU figure is proportional to the rise, so the same 4.0 GPM needs 139,944 BTU/hr at a 70°F rise and 99,960 BTU/hr at a 50°F rise. A unit rated 7 GPM at a 35°F rise delivers only about 3.5 GPM at a 70°F rise — read the rise on the rating, not just the GPM.

The AHRI peak-hour worksheet — gallons of hot water per use.

Use in the busiest hourGallons each (AHRI)DOE worksheet
Shower2020
Bath (tub fill)20— (not counted)
Shaving22
Hand and face washing4— (not counted)
Hair shampoo4— (not counted)
Hand dishwashing43 (with food prep)
Automatic dishwasher147
Food preparation53 (with hand dishwashing)
Automatic clothes washer3225 top-loader · 15 high-efficiency

AHRI’s figures assume no water-saving fixtures. AHRI’s worked example: 3 showers, a shave, a shampoo and hand dishwashing = 70 gallons. DOE’s worked example: 3 showers, a shave and hand dishwashing = 65 gallons (DOE prints 66; the rows add to 65).

First-hour rating by tank size and fuel — typical label values. Check the yellow EnergyGuide label of the model you buy; the same size varies by model.

Tank sizeGas — typical FHRElectric — typical FHRHeat pump — typical FHR
30 gallons51–65 (short / lowboy, 30,000–32,000 BTU)45—
40 gallons67 (label range 64–84)53 (label 54–55)—
50 gallons81 (label range 76–85)61 (label range 57–63)66
65 gallons— (special order)— (stops at 50)75
75 gallons125 (75,100 BTU burner)— (stops at 50)—
80 gallons—— (stops at 50)87 (label 86–95)

Sources: calculatedhome’s published table (gas 40 → 67, 50 → 81, 75 → 125; electric 30 → 45, 40 → 53, 50 → 61; heat pump 50 → 66, 65 → 75, 80 → 87); berksconnect’s manufacturer ranges; knowthefix’s ENERGY STAR and spec-sheet ranges; Rheem spec sheets via housecarecosts. FHR ≈ 0.7 × tank gallons + one hour of recovery — gas about 57 gph at the 67°F test rise (40,000 BTU burner at 80%), electric about 27 gph (4,500 W elements at 98%).

Household size — the quick cross-check (Angi, updated 31 July 2026). Rules of thumb: tank ≈ 20 gallons base + 10 per person; tankless ≈ 5 GPM base + 1 per person.

HouseholdTank sizeTankless flow
1–2 people30–40 gallons6–8 GPM
2–3 people40–50 gallons7–9 GPM
3–4 people50–60 gallons8–10 GPM
4–5 people60–70 gallons9–11 GPM
5–6 people70–80 gallons10–12 GPM
6–7 people80–90 gallons11–13 GPM
7–8 people90–100 gallons12–14 GPM

Tankless flow by fixture (running at the same time).

Fixture running at onceFlow (GPM)
Shower (2.0 gpm head; 1.5 low-flow, 2.5 federal maximum)2.0
Sink / small tap0.5
Automatic dishwasher (while filling)0.5
Clothes washer (while filling)2.0

BTU/hr = GPM × 8.33 × temperature rise (°F) × 60. Two showers at 2.0 GPM = 4.0 GPM: at a 70°F rise that is 139,944 BTU/hr (41.0 kW); at a 50°F rise it is 99,960 BTU/hr (29.3 kW); at a 73°F rise, 3.2 GPM is 116,753 BTU/hr (34.2 kW).

Uniform Energy Factor (UEF) — typical ranges and the values this page uses. UEF is the federal efficiency rating (DOE test procedure, 10 CFR 430 Appendix E): heat delivered divided by energy in, including standby, cycling and recovery losses. A heat pump’s UEF is above 1 because it moves heat instead of making it.

TypeTypical UEF rangeUsed here
Standard electric tank0.90–0.950.92
Standard gas tank0.60–0.700.64
High-efficiency (condensing) gas tank0.75–0.86—
Gas tankless0.82–0.990.82
Heat pump (hybrid) tank3.0–4.03.5

Annual running cost at 60 gallons a day (published anchors, at their rates) and at 68 gallons a day (this page, $0.16/kWh, $1.50/therm, 70°F rise). At 60 gallons a day: electric about $651, gas tank about $299, heat pump about $171 by this page’s formula — against calculateitnow’s $662 electric / $296 gas / $174 heat pump and heaterguidehq’s $613 electric / $302 gas tank / $161 heat pump / $221 gas tankless. The anchors differ because the rates differ; the formula is the same. At 68 gallons a day (4 people × 17): electric $738, gas tank $339, heat pump $194, tankless gas $265.

Inlet water temperature — the sizing swing.

RegionWinter inlet water
North~40°F (4°C) — Boston groundwater 47°F
Central~50°F (10°C)
South~70°F (21°C) — Orlando groundwater 72°F
Southwest / Gulf~60°F (16°C) (Ruud)
Federal test condition58°F in, 125°F out (67°F rise)

Installed prices (national ranges, 2025–26). Gas tank $1,200–$3,000 · electric tank $900–$2,000 · heat pump tank $2,800–$5,000 · whole-house gas tankless $2,500–$5,600 (HomeGuide) — Angi’s figure for a new tankless install is $5,400–$7,400, which covers conversions needing a bigger gas line and new venting. A gas tankless needs about 199,000 BTU of gas capacity where a standard tank needs 40,000 — the gas-line upsize is the hidden cost of the conversion.

The field, as it stands. The exact-phrase top four are all small specialist tools: levelcalc (people × 12 + baths × 20 + dishwasher × 6 + washer × 7), gettheamount (fixture-by-fixture, tank = peak ÷ 0.9, 61 gallons for the 4-person household), delimetra (60% of the day’s use, 48 gallons) and septiwellguide (10 × people + 12 × baths + 6 + 8, 78 gallons). No giant — Inch, Omni, CalculatorSoup and Calculator.net are absent. The question variant (“what size water heater do I need”) is held by Angi (household table, tankless $5,400–$7,400), calculatedhome (DOE worksheet, FHR table by fuel), nailthemath (AHRI worksheet, 70-gallon example) and ARS (A.O. Smith table). The cost field (“water heater cost calculator”) is held by wolveyes, howmuchwatts, calculateitnow.dev ($662 electric / $296 gas / $174 heat pump at 150 litres a day) and heaterguidehq ($613 / $161 / $302 / $221 at 60 gallons a day). None of them prints the 48-to-101-gallon spread, none of them shows the DOE-vs-AHRI disagreement, and none of them models the heat-pump upsizing past the 50-gallon electric limit — which is what this page is built to do.

Measurement tips

  • Size from the busiest hour, not the daily total. Nobody runs out of hot water over the course of a day — they run out between 6:45 and 7:45 in the morning. The daily total (68 gallons for 4 people) is for the running cost; the size comes from the single busiest hour (70 gallons on the defaults). A tank sized to the daily total is the wrong tank.
  • Buy the first-hour rating, not the gallons. The rating is on the yellow EnergyGuide label as “Capacity (first hour rating)”. A 40-gallon gas tank (FHR 67) out-delivers a 50-gallon electric tank (FHR 61) — and two 40-gallon gas tanks can differ by 20 gallons in FHR. Read the label of the model in front of you.
  • Run the washer outside the shower hour. A washer load is 32 gallons in the AHRI worksheet — the second-biggest single draw after a bath. Moving one load out of the peak hour can drop the peak by 32 gallons, which is often a whole tank size. The same goes for the dishwasher (14 gallons).
  • When the peak is close to a tank’s FHR, go up a size. A 70-gallon peak on a 40-gallon gas tank (FHR 67) is 3 gallons short — and that is 3 gallons of cold water in the last shower. The price step is small (about $20 between a 40- and a 50-gallon gas tank on the same line), and the cost of being wrong is a cold shower every morning.
  • On a tankless, size for the coldest water, not the average. The BTU figure follows the temperature rise, so the same 4.0 GPM needs 139,944 BTU/hr at a 70°F rise and 99,960 at a 50°F rise. Size it for January water (40°F in the north) and it will be oversized in July — which is fine, because an oversized tankless just modulates down.
  • Read the rise on a tankless rating, not just the GPM. A unit rated 7 GPM at a 35°F rise delivers only about 3.5 GPM at a 70°F rise. The GPM without the rise is not a rating — it is a headline. Match the rise to your groundwater first, then read the GPM.
  • A heat pump tank needs air and space. It pulls heat from the surrounding air, so it needs about 700–1,000 cubic feet of space and air at or above 45°F — a warm basement, not a freezing garage. In a cold garage it falls back to its resistance elements, and the UEF 3.5 becomes 0.92. Check the room before you check the price.
  • Set 120°F and fit a mixing valve if you go hotter. 120°F is hot enough to shower and cool enough to limit scalding. 140°F scalds in seconds and needs a mixing valve at the tap — and the hotter setpoint also raises the standby loss and the annual cost, because the rise is bigger.
  • Budget the gas line on a tankless conversion. A standard tank needs about 40,000 BTU/hr of gas; a whole-house tankless needs up to 199,000. The gas-line upsize (usually 1/2 inch to 3/4 inch), the venting and the condensate drain are the costs that turn a $2,500 unit into a $5,400–$7,400 install. Get the gas line quoted with the unit, not after it.
  • Descale a tankless every year in hard water. Scale in the heat exchanger is the repair that costs $150–$350 and the failure that ends a tankless early. A tank tolerates hard water for a decade; a tankless does not. If your water is hard, budget the descale — or the water softener — with the unit.

Common mistakes

  • Buying gallons instead of first-hour rating. A 50-gallon tank does not deliver 50 gallons of hot water — it delivers about 35 before the outlet cools, plus whatever the burner puts back in the hour. The 50-gallon electric (FHR 61) loses to the 40-gallon gas (FHR 67) on the number that matters. Size by FHR, and read it off the yellow label.
  • Sizing from the daily total. 68 gallons a day for 4 people sounds like a 70-gallon tank — but the tank has all day to reheat, and the morning needs 70 gallons in one hour. The daily total is for the running cost; the size comes from the busiest hour. A tank sized to the daily total runs cold at 7 am.
  • Counting only the showers. Three showers are 60 gallons, but the shave, the shampoo and the hand dishwashing add 10 more — and a dishwasher load adds 14, a washer load 32. The worksheet lines that look small are the ones that push the peak over the next tank’s FHR.
  • Using the DOE worksheet and the AHRI worksheet as if they were the same. They disagree by 5 gallons on the default morning and by 14 on a morning with a dishwasher and a washer load. A calculator that prints one number without saying which worksheet it is has picked a side without telling you — and the side it picks moves the answer a tank size.
  • Trusting a household table over your own morning. Angi’s table puts 4 people at 50–60 gallons of tank — but if your 4 people all shower in the same hour with a washer running, the worksheet says 102 gallons. The table counts an average household; the worksheet counts yours. When they disagree, trust the worksheet.
  • Sizing a tankless on summer water. A unit that delivers 7 GPM at a 35°F rise delivers about 3.5 GPM at a 70°F rise. Size it on the July inlet temperature and it will be undersized in January, when the water is 40°F and the rise is 80°F. Size on the coldest water your home sees.
  • Putting the heat-pump payback credit in after it ended. The Section 25C credit ($600) ended for installations completed after 31 December 2025. Several guides still quote it, and a payback that includes it is overstated by $600. This page’s payback has no credit in it.
  • Forgetting the electric 50-gallon ceiling. Standard electric tanks stop at 50 gallons (FHR 61). A household that needs 70 gallons on electric does not need a bigger electric tank — there isn’t one. It needs a heat pump tank (65 gallons, FHR 75) or a second tank. Buying a second 50-gallon electric because the first was too small is the expensive way to learn it.
  • Setting 140°F without a mixing valve. 140°F water scalds in seconds, and it raises the standby loss and the annual cost, because the temperature rise is 20°F bigger. If you need 140°F for a dishwasher or a legionella concern, fit a thermostatic mixing valve and keep the tap at 120°F.
  • Ignoring the gas line on a tankless swap. A tankless needs up to 199,000 BTU/hr where the old tank needed 40,000. The gas-line upsize, the venting and the condensate drain are not in the unit price — and they are the reason Angi’s new-tankless figure is $5,400–$7,400 while the unit alone is $1,500–$2,600. Quote the whole conversion.

Factors that affect accuracy

  • Showers in the busiest hour — 20 gallons each, and the biggest line. Three showers are 60 of the 70-gallon default peak. Every shower added or removed moves the peak by 20 gallons — which is a third of a tank size. Staggering the showers across two hours is the cheapest resize there is.
  • Fuel — recovery speed is the FHR. Gas reheats at about 57 gallons an hour at the test rise, electric at about 27. That is why the 40-gallon gas tank (FHR 67) beats the 50-gallon electric (FHR 61), and why the same peak needs a 50-gallon gas tank, a 65-gallon heat pump tank, or no electric tank at all.
  • Inlet temperature — the tankless swing and the cost swing. Winter water at 40°F makes a 80°F rise where summer water at 70°F makes a 50°F rise. The tankless BTU figure follows the rise directly; the annual cost follows it too — the same 68 gallons a day costs about 60% more to heat at an 80°F rise than at a 50°F rise.
  • Setpoint — every degree costs money. The heat needed is proportional to the rise, so raising the setpoint from 120°F to 140°F on 50°F inlet water raises the rise from 70°F to 90°F — about 29% more heat, and about 29% more on the annual cost, for water that then needs a mixing valve to be safe at the tap.
  • Daily gallons — the cost driver, not the size driver. The annual cost is proportional to the gallons a day: 68 gallons a day is $738 a year on electric at these rates, 34 gallons is $369. The size does not move with the daily total at all — it moves with the busiest hour. A household that uses little water but all at once needs a big tank and pays a small bill.
  • Showerhead flow — the tankless multiplier. Two showers at 2.5 GPM need 5.0 GPM and 174,930 BTU/hr at a 70°F rise; at 1.5 GPM they need 3.0 GPM and 104,958 BTU/hr. A low-flow head is a smaller tankless unit, a smaller gas line and a smaller bill — the cheapest upgrade on this page.
  • Washer and dishwasher timing — 46 gallons of movable load. A washer load (32 gallons) and a dishwasher load (14 gallons) in the peak hour add 46 gallons to the peak — more than two showers. Running either outside the shower hour is often the difference between a 50-gallon and a 75-gallon tank.
  • UEF — the cost multiplier. The same 14.5 million BTU a year costs $738 on an electric tank (UEF 0.92), $339 on gas (0.64), $194 on a heat pump (3.5) and $265 on a tankless gas (0.82) at these rates. The UEF is the whole cost story: the heat pump moves heat instead of making it, so it uses about a quarter of the electricity.
  • Household size — the table, not the worksheet. Angi’s table adds 10 gallons of tank (or 1 GPM of tankless) per person on a 20-gallon (or 5 GPM) base. It is a good cross-check and a bad primary method — it cannot see that your four people shower together, or that they shower one at a time across the morning.
  • Recovery — what the FHR is made of. FHR is about 70% of the tank plus one hour of recovery. A bigger burner raises the FHR without raising the tank: a 40-gallon gas tank with a 40,000 BTU burner rates 84 gallons on one maker’s sheet, against 67 for the standard-burner model. The burner size is the quiet variable in the FHR table.

Sources & assumptions

  • Method — the AHRI peak-hour worksheet is the primary method. Nail the Math's sizing guide (live read 2026-11-24, published 2026-11-07, sources AHRI Worksheet for Estimating Peak Hour Demand / First Hour Rating, DOE Building America, 10 CFR 430 Subpart B Appendix E): shower 20 · bath 20 · shaving 2 · hand and face washing 4 · hair shampoo 4 · hand dishwashing 4 · automatic dishwasher 14 · food preparation 5 · automatic clothes washer 32 gallons per use; worked example 3 showers + shave + shampoo + hand dishwashing = 70 gallons; DOE Building America rule — pick a tank with a first-hour rating equal to or greater than the peak-hour demand. HVAC Solver and nrtechstudio's calculator (live reads 2026-11-24) print the same nine AHRI figures and the same 70-gallon anchor check.
  • DOE worksheet — Kitchen and Bath Renovators' FHR research (live read 2026-11-24, DOE Energy Saver archived 2026-07-02): shower 20 · shaving 2 · hand dishwashing or food prep 3 · automatic dishwasher 7 · top-loader washer 25 · H-axis washer 15; worked example 3 showers + shave + hand dishwashing printed as 66 gallons, rows add to 65 — a one-gallon slip that does not change the method; FHR test conditions 58°F supply, 125°F outlet, 3.0 gpm draw; draw bands very small under 18 · low 18 to under 51 · medium 51 to under 75 · high 75 and up (Appendix E, Table I). House Care Costs (live read 2026-11-24) reproduces the same DOE table and the same 65-vs-66 note, and adds the Rheem spec-sheet checks (40-gallon gas 64–84, 50-gallon electric 57–63).
  • First-hour rating — CalculatedHome's water heater size calculator (live read 2026-11-24): "Typical first-hour ratings run about 67, 81 and 125 gallons for 40-, 50- and 75-gallon gas tanks; 45, 53 and 61 for 30-, 40- and 50-gallon electric tanks; and 66, 75 and 87 for 50-, 65- and 80-gallon heat pump tanks. Standard electric tanks stop at 50 gallons"; worked example "60 + 5 = 65 gallons, so a 40-gallon gas tank rated 67 covers it"; "Under the Department of Energy's newer rule, effective May 6, 2029, electric tanks over 35 gallons will need heat pump technology." Berks Connect (live read 2026-11-24): 30-gallon gas short 51–65 · 40-gallon gas 64–84 · 50-gallon gas 76–85 · 75-gallon gas 125 · 30-gallon electric 44–48 · 40-gallon electric 55 · 50-gallon electric 57–63 · 80-gallon heat pump 86. Know the Fix (live read 2026-11-24): 50-gal electric 58–63 · 40-gal heat pump 45–66 · 50-gal heat pump 50–77 · 40-gal standard gas 67–81 · 50-gal standard gas 75–85 · 80-gal heat pump 88–95.
  • FHR formula and recovery — The Building Code's first-hour-rating guide (live read 2026-11-24): FHR = usable storage + one hour of recovery; usable storage 70% of the tank; worked example 40-gallon gas, 40,000 BTU/hr burner at 80%, 70°F rise → 28 + 55 = 83 gallons; formula-based table (70% usable, 70°F rise) gas 30 → 76 / 40 → 83 / 50 → 90 / 75 → 108 / 80 → 111, electric 30 → 47 / 40 → 54 / 50 → 61 / 75 → 79 / 80 → 82. WaterHeaterLab (live read 2026-11-24): usable draw ~70% of nominal; electric recovery 20.5 gal/hr (4,500 W, 90°F rise); gas recovery 40.5 gal/hr (40,000 BTU, 90°F rise).
  • Household table and tankless install cost — Angi's sizing guide (live read 2026-11-24, updated 31 July 2026): tank 1–2 people 30–40 · 2–3 40–50 · 3–4 50–60 · 4–5 60–70 · 5–6 70–80 · 6–7 80–90 · 7–8 90–100 gallons; tankless 1–2 6–8 · 2–3 7–9 · 3–4 8–10 · 4–5 9–11 · 5–6 10–12 · 6–7 11–13 · 7–8 12–14 GPM; rules 20-gallon base + 10 per person (tank), 5 GPM base + 1 per person (tankless); "Expect to pay $5,400 to $7,400 to install a new tankless water heater"; groundwater Boston 47°F, Orlando 72°F. Angi's tankless-size guide: most common 7–9 GPM, 2–12 GPM range, install $1,300–$3,700.
  • UEF — ElectricVsGas (live read 2026-11-24): standard electric resistance 0.90–0.95 · standard gas tank 0.60–0.70 · gas condensing 0.75–0.86 · heat pump 3.0–4.0 (3.5 typical); annual-cost table heat pump 3.5 $203/yr · high-efficiency gas 0.82 $234 · standard gas 0.67 $286 · electric 0.92 $774. HVACMore's glossary (live read 2026-11-24): basic gas tank 0.58 · condensing gas 0.70–0.82 · electric resistance 0.92–0.95 · heat pump 2.5–4.0 · gas tankless 0.82–0.99; federal minimum UEF tables (California Energy Commission guide): 40-gal gas 0.58–0.64 by draw band, 50-gal electric 0.92.
  • 25C credit ended — ElectricVsGas (live read 2026-11-24): "The federal 25C tax credit for heat pump water heaters discussed in this article has expired. The One Big Beautiful Bill Act (P.L. 119-21, signed July 4, 2025) terminated the Section 25C credit for installations completed after December 31, 2025. The $600 credit is no longer available."
  • Installed prices — Spetz's 2026 water heater cost guide (live read 2026-11-24): gas tank 40–50 gal $1,200–$3,000 · electric tank $900–$2,000 · 50-gal heat pump $2,800–$5,000 · whole-house gas tankless $2,500–$5,600 (Angi, HomeGuide, Fixr); winter inlet water 40°F north, 50°F south, 60°F Southwest and Gulf (Ruud). TwoPro's tankless cost guide (live read 2026-11-24): whole-house tankless $1,400–$5,600 installed (HomeGuide), Angi typical $1,400–$3,900, labour $600–$2,500.
  • Cost anchors — field teardown 2026-11-23 (SERP snapshots, not GSC): calculateitnow.dev 150 L/day → $662/yr electric (UEF 0.92) / $296 gas / $174 heat pump (3.5); heaterguidehq 60 gal/day → $613 electric / $161 heat pump / $302 gas tank / $221 gas tankless / $575 electric tankless. This page's formula at 60 gal/day, $0.16/kWh, $1.50/therm, 70°F rise gives $651 / $299 / $171 — the anchors differ because the rates differ; the formula is the same.
  • Method spread — field teardown 2026-11-23 (SERP snapshots, not GSC): levelcalc #1 (peak = people × 12 + baths × 20 + dishwasher × 6 + washer × 7; 4 people/2 baths → 101 gal → 80-gal tank, 5 GPM) · gettheamount #2 (fixture-by-fixture, tank = peak ÷ 0.9; peak 61 gal → 80 gal, 4 GPM, 139,944 BTU/hr at a 70°F rise) · delimetra #3 (peak = 60% of the day; FHR ≈ 0.7 × tank + recovery; 4 people × 20 gal, 4,500 W → 40-gal tank, FHR 54 gal, recovery 26.3 gph, 14.9 kWh/day) · septiwellguide #4 (peak = 10 × people + 12 × baths + 6 + 8; 78 gal → 80 gal, 6.5 GPM). DOE average use 17 gal/person/day, 50.6 gal/day per household (nailthemath, from DOE). ENERGY STAR NextGen heat-pump minimum 59 gal for a 2–2.5-bath, 3-bedroom home (nailthemath).

Figures checked on 28 November 2026 as part of the site-wide test run (3239 automated checks, all passing). See how we calculate and test.

How this calculator was checked

Figures checked 24 November 2026. Each case below was recomputed from the calculator's own formula and matched the tool's output.

Test inputsExpected result
4 people, 2 baths — 3 showers, 1 shave, 1 shampoo, 1 hand dishwashing in the busiest hour (defaults)AHRI peak 70 gal (265.0 L) / DOE peak 65 gal (246.1 L); FHR needed 70; gas 50-gal (FHR 81) covers, electric 50-gal (FHR 61) does NOT, heat pump 65-gal (FHR 75) covers
DOE worked example — 3 showers, 1 shave, 1 hand dishwashing65 gal (DOE prints 66; the rows add to 65) — 40-gal gas (FHR 67) covers, 50-gal electric (FHR 61) does NOT
AHRI worked example — 3 showers, 1 shave, 1 shampoo, 1 hand dishwashing70 gal — 40-gal gas (FHR 67) is 3 gal short; 50-gal gas (FHR 81) covers
Tankless — 2 showers at once, 2.0 gpm heads, 70°F rise (120°F setpoint, 50°F inlet)4.0 GPM → 139,944 BTU/hr (41.0 kW)
Tankless — 2 showers, 3.2 GPM, 73°F rise116,753 BTU/hr (34.2 kW)
Running cost — 68 gal/day (4 people × 17), 70°F rise, $0.16/kWh, $1.50/thermElectric $738/yr (UEF 0.92) · gas tank $339/yr (UEF 0.64) · heat pump $194/yr (UEF 3.5) · tankless gas $265/yr (UEF 0.82)
Heat pump payback — HP $3,900 installed vs electric $1,450$2,450 premium ÷ $544/yr saving = about 4.5 years (no 25C credit — it ended 31 Dec 2025)
Delimetra check — 4 people × 20 gal = 80 gal/day, electric, UEF 0.92, 70°F rise14.9 kWh/day
Metric — 70 gal peak, 65 gal DOE, 68 gal/day265.0 L · 246.1 L · 257.4 L/day; 70°F rise = 38.9°C

What this check does not cover

  • First-hour ratings are typical label values for standard lines — the same size varies by model (Rheem 40-gallon gas: 64–84 gal), so always read the yellow EnergyGuide label of the model you buy.
  • AHRI assumes no water-saving fixtures; low-flow showerheads cut the real draw below the worksheet figure, so the tool’s answer carries margin on a modern home.
  • DOE and AHRI disagree on the dishwasher (7 vs 14 gal) and the washer (25/15 vs 32 gal) — the tool prints both and sizes from the larger (AHRI).
  • Running costs heat the same gallons at the same rise for all four types at your rates; standby loss is inside the UEF, and a heat pump in a cold garage or a tankless at minimum flow will differ.
  • Installed prices are national ranges (Angi, HomeGuide, Fixr 2025–26); your quote depends on the gas line, venting, panel, permits and city.
Please note: material estimates are approximate. Always confirm product coverage with the manufacturer and buy a little extra for cuts, waste and future repairs.

What this calculator doesn't do

  • This is a planning calculation, not a plumbing design. It sizes from the AHRI peak-hour worksheet and the published first-hour ratings of standard tanks — it does not check your gas-line capacity, venting, electrical panel, water pressure, recirculation loop, local code, or the space the tank has to fit in. A licensed plumber sizes the install; this page tells you which size to ask for before you call one.
  • The first-hour ratings in the table are typical label values for standard residential lines (calculatedhome's published table: gas 40 → 67, 50 → 81, 75 → 125; electric 30 → 45, 40 → 53, 50 → 61; heat pump 50 → 66, 65 → 75, 80 → 87). The same size varies by model — Rheem's 40-gallon gas tanks run 64 to 84 gallons — so the rating on the yellow EnergyGuide label of the model in front of you is the number that counts, not this table.
  • The AHRI worksheet assumes no water-saving fixtures. A 2.0 gpm showerhead for 8 minutes uses about 16 gallons of mixed water, not 20 — but the worksheet's 20-gallon figure is the conservative planning number, and sizing to it is what keeps the fourth shower hot. If every fixture in your home is low-flow, the tool's answer has margin built in; the page says by how much.
  • The DOE worksheet and the AHRI worksheet disagree on two lines — the automatic dishwasher (7 gallons DOE, 14 AHRI) and the clothes washer (25 DOE for a top-loader, 15 for a high-efficiency machine, 32 AHRI) — so the same morning adds to 65 gallons by DOE and 70 by AHRI. The tool shows both, so the spread is visible instead of hidden; it sizes from the AHRI figure, the larger of the two.
  • The running-cost comparison heats the same gallons at the same temperature rise for all four types, at the rates you enter — it does not model standby loss separately (it is already inside the UEF), it does not model a heat pump's slower recovery in a cold garage, and it does not model a tankless unit's minimum flow or its cold-water sandwich. The annual figures are for comparing types, not for budgeting to the dollar.
  • Installed prices are national ranges from Angi, HomeGuide and Fixr (2025–26): gas tank $1,200–$3,000, electric tank $900–$2,000, heat pump $2,800–$5,000, whole-house gas tankless $2,500–$5,600 (Angi's new-tankless figure is $5,400–$7,400). Your quote depends on the gas line, venting, panel, permits and your city — get three written quotes for the same size and type.

Water Heater Size Calculator — What Size Water Heater Do I Need? — frequently asked questions

What size water heater do I need?

Add up your busiest hour with the AHRI worksheet, then buy a tank whose first-hour rating is at least that number. Three showers, a shave, a shampoo and hand dishwashing is 70 gallons — so a 50-gallon gas tank (typical FHR 81) covers it, a 65-gallon heat pump tank (FHR 75) covers it, and no standard electric tank does (the biggest is 50 gallons, FHR 61). The gallon number on the box is not the size; the first-hour rating on the yellow EnergyGuide label is. Enter your own morning above and the tool works your exact size out.

How many gallons of water heater do I need for a family of 4?

50–60 gallons of tank by the household table — but check the worksheet. Angi’s table puts 4 people at 50–60 gallons of tank (3–4 people) or 60–70 (4–5 people), and 8–10 GPM tankless. The worksheet is more precise: if your 4 people shower in the same hour, the peak is 70 gallons and the answer is a 50-gallon gas tank (FHR 81) or a 65-gallon heat pump tank (FHR 75). If they shower across the morning, a 40-gallon gas tank (FHR 67) is enough. The table counts an average household; the worksheet counts yours.

What is first hour rating (FHR)?

How much hot water a tank can deliver in one hour, starting full and hot. It is usable storage (about 70% of the tank) plus one hour of recovery, measured by the federal test at 3.0 gpm with 58°F water in and 125°F out. It is printed on the yellow EnergyGuide label as “Capacity (first hour rating)”. A 40-gallon gas tank typically rates 67 gallons, a 50-gallon gas tank 81, a 75-gallon gas tank 125; a 50-gallon electric tank rates 61; a 50-gallon heat pump tank rates 66. Size by FHR, not by gallons.

Is a 40-gallon water heater enough for a family of 4?

A 40-gallon gas tank usually is; a 40-gallon electric usually is not. A 40-gallon gas tank (typical FHR 67) covers a 65-gallon peak — three showers, a shave and hand dishwashing by the DOE worksheet — but not the 70-gallon AHRI peak for the same morning. A 40-gallon electric tank (FHR 53) covers neither. If your household’s busiest hour is under 65 gallons, the 40-gallon gas is enough; if it is 70 or more, step up to the 50-gallon gas (FHR 81) or a 65-gallon heat pump (FHR 75). The answer depends on the morning, not the headcount.

How do I calculate peak hour demand?

Count every hot-water use in the busiest hour and multiply by the AHRI gallons per use. Shower 20 · bath 20 · shave 2 · hand and face washing 4 · shampoo 4 · hand dishwashing 4 · automatic dishwasher 14 · food preparation 5 · automatic clothes washer 32. Three showers, a shave, a shampoo and hand dishwashing is 60 + 2 + 4 + 4 = 70 gallons. The DOE worksheet gives 65 for a similar morning (dishwasher 7, washer 25, no shampoo line) — the tool prints both and sizes from the AHRI figure, the larger of the two.

What size tankless water heater do I need?

Add up the flow of everything running at the same time, at your temperature rise. Two showers at 2.0 gpm need 4.0 GPM; add 0.5 per tap, 0.5 for a dishwasher filling, 2.0 for a washer filling. Then BTU/hr = GPM × 8.33 × rise × 60 — 4.0 GPM at a 70°F rise is 139,944 BTU/hr (41.0 kW). Angi’s household table puts 3–4 people at 8–10 GPM, which assumes more fixtures at once than two showers. Size on your coldest inlet water (40°F in the north), not the summer figure.

How much does it cost to run a water heater per year?

At 68 gallons a day (4 people × 17), a 70°F rise, $0.16/kWh and $1.50/therm: electric tank $738, gas tank $339, heat pump $194, tankless gas $265 a year. The formula is daily gallons × 365 × 8.33 × rise, divided by the UEF and your rate. The heat pump is the cheapest to run by a wide margin (UEF 3.5 against 0.92 for electric resistance) — but its installed price is higher, so the payback is about 4.5 years against an electric tank at these rates. Change the rates and the daily gallons above and the tool reprices all four.

Is a heat pump water heater worth it?

On running cost, yes — on payback, it depends on what it replaces. At 68 gallons a day it costs about $194 a year against $738 for a standard electric tank, a $544 saving — and the $2,450 installed premium pays back in about 4.5 years. Against a gas tank ($339 a year) the saving is $145 a year and the payback is about 12.4 years. It needs 700–1,000 cubic feet of air at or above 45°F, so a warm basement works and a freezing garage does not. And there is no federal credit in the payback: the 25C credit ended for installations completed after 31 December 2025.

What temperature should I set my water heater to?

120°F (48.9°C) is the usual recommendation. It is hot enough to shower comfortably and cool enough to limit scalding. 140°F (60°C) scalds in seconds and needs a thermostatic mixing valve at the tap — and it raises the annual cost by about 29% on 50°F inlet water, because the rise grows from 70°F to 90°F. The federal efficiency test uses 125°F out, and the tool’s default setpoint is 120°F.

Can I replace a 50-gallon electric water heater with a bigger one?

Not with a bigger standard electric tank — they stop at 50 gallons. A household that needs more than a 50-gallon electric’s 61-gallon first-hour rating has three options: a heat pump tank (50, 65 or 80 gallons — FHR 66, 75, 87), a second tank, or a tankless unit. Under the DOE’s newer rule, effective 6 May 2029, electric tanks over 35 gallons will need heat pump technology anyway. The 65-gallon heat pump tank (FHR 75) is the usual step up from a 50-gallon electric.

How many litres is a 50-gallon water heater? (metric)

189.3 litres — and its first-hour rating of 61 gallons is 230.9 litres. 1 US gallon is 3.78541 litres. The tool’s default peak of 70 gallons is 265.0 litres, the DOE cross-check of 65 gallons is 246.1 litres, and 68 gallons a day is 257.4 litres a day. A 40-gallon tank is 151.4 litres, an 80-gallon tank is 302.8 litres. If your tank is labelled in litres, divide by 3.78541 to get the US gallons this page sizes in — a 200-litre tank is about 53 US gallons.

What size water heater do I need in litres? (metric)

Work the worksheet in gallons, then convert: a 70-gallon peak hour is 265 litres, and you need a tank rated at least 265 litres in the first hour. The first-hour rating converts the same way — a 50-gallon gas tank’s 81-gallon FHR is 306.6 litres, a 65-gallon heat pump’s 75-gallon FHR is 283.9 litres. Temperatures convert as °C = (°F − 32) × 5 ÷ 9: a 120°F setpoint is 48.9°C, a 70°F rise is 38.9°C, and 40°F inlet water is 4.4°C. A tankless needing 4.0 GPM at a 70°F (38.9°C) rise is 15.1 litres a minute at a 38.9°C rise — 139,944 BTU/hr, or 41.0 kW.

Next step

Take the tank size and the first-hour rating to your plumber — and check the running cost first with the electricity cost calculator, the load behind the hot water with the BTU calculator and the heat pump size calculator, and the room the tank sits in with the radiator size calculator and the insulation calculator before you buy, because a heat pump tank needs warm air around it and a tankless needs a gas line that can feed it. If the peak is close to a tank's rating, go up a size — the price step is small and the cost of being wrong is a cold shower every morning.

Save this estimate: use the Copy link button in the results box above to share these exact inputs, or Print results for a paper copy to take to the store.