Dehumidifier Size Calculator — What Size Do I Need? Pints Per Day

A dehumidifier is sized in pints per day — how much water it removes in 24 hours under a standard test. Too small and the basement stays musty, the walls sweat and mould grows; too big and you pay for capacity you never use, on a unit that short-cycles. This dehumidifier size calculator works it out the way ENERGY STAR publishes it: a range for your floor area and how damp the space is — 20–30 pints a day for a moderately damp space under 2,000 sq ft, 25–40 for a very damp one, 30–50 for a wet one — then interpolates by your exact area, corrects for ceiling height and extra moisture sources, and rounds up to the next 5 pints. It also shows the two numbers every other chart gives you, so you can see why they disagree: the classic AHAM figure on the old 80°F scale, converted with ENERGY STAR's own table, and the retailer rule of thumb (1 pint per 50 sq ft) that runs about 43% high. Then it prices the running cost at the ENERGY STAR efficiency minimum for the size class, and tells you whether the space needs a low-temperature model, a desiccant unit, or continuous drainage. For the fan that moves the damp air out of a bathroom, use the bathroom fan size calculator; for stopping the damp at its source, the insulation calculator; for the cost of heating the space, the heating cost calculator; and for pricing any appliance on your electricity rate, the electricity cost calculator.

Quick answer: A 1,000 sq ft very damp basement with an 8 ft ceiling needs a 35-pint dehumidifier (2019 rating) — the ENERGY STAR band is 25–40 pints, and 1,000 sq ft sits halfway up it. That is about 60 pints on the old pre-2019 label, so buy a 35-pint unit (or a 50-pint one for headroom) — it will actually collect about 30–39 pints a day in a real 65°F basement, and cost about $69 a year to run at 3 hours a day. A 500 sq ft moderately damp room needs only 25 pints, and anything over 50 pints a day needs a whole-basement or ducted unit. Enter your room below for your exact numbers.
The longest wall of the space, wall to wall. The ENERGY STAR method works from floor area, so a wrong length is a wrong answer.
The shorter wall. For an L-shaped basement, split it into two rectangles that do not overlap and add the areas — or use the floor-area field below.
If you already know the floor area, enter it here and it replaces length × width. If it disagrees with length × width, clear length and width first — the tool flags the mismatch rather than guessing which one you meant.
Floor to ceiling — 8 ft (2.4 m) is standard. Above 8 ft the figure scales by height ÷ 8, because there is more air to dry.
Basements and crawlspaces take moisture through the ground, so the retailer row adds 10–15% for them — the ENERGY STAR primary does not. A whole-home space over 50 pints a day needs a ducted unit.
Judge by what you see and smell, or by a hygrometer — the RH bands are ENERGY STAR's. If in doubt, pick the wetter band: an undersized unit is the expensive mistake. Standing water is a drainage job first, not a bigger unit.
Temperature decides the type, not just the size: a standard compressor unit ices up below 65°F. A cool basement needs a low-temperature model with auto-defrost; below 55°F you need a desiccant or LGR unit.
Drying clothes indoors releases litres of water into the air. Each extra moisture source adds 5 pints a day.
Open windows and doors keep bringing damp outside air in. If the space is usually kept closed, leave this at No.
People breathe out moisture and carry it in on clothes and shoes. A busy family room or a home gym counts; a storage basement does not.
A kitchen or a bathroom next door adds steam every day. Count it if the moisture source shares air with the space.
If you already own a dehumidifier, empty the bucket and measure what it collects in 24 hours. The tool takes the larger of the calculated figure and your measured figure, rounded up to the next 5 pints — a measurement raises the answer, never lowers it.
Your price per kWh, from your bill — 0.1831, not 18.31. The default is the US average residential price, 18.31 cents per kWh (EIA, July 2026). In the UK, the Ofgem price-cap rate for October–December 2026 is 26.32p (enter 0.2632 with £).
How many hours a day the unit runs at full capacity. The default is 3 — the DOE counts 1,095 operating hours a year, which is 3 hours a day at full capacity. A unit that runs 24/7 in a wet basement costs eight times this figure.
The rate above is entered in this currency per kWh. The tool never converts between currencies — it prices your energy in the money your bill is in.

Planning this project? Save to Pinterest to find this calculator again later.

How to use the Dehumidifier Size Calculator — What Size Do I Need? Pints Per Day

  1. Measure the space. Length × width, wall to wall, in feet or metres — or enter the floor area directly. A 25 × 40 ft basement is 1,000 sq ft. Measure the ceiling height too: at 8 ft the chart applies as written, above 8 ft the figure scales by height ÷ 8.
  2. Pick the space type. A basement or crawlspace takes moisture through the ground; a garage is unheated with doors opening often; a living room is heated. The space type changes the drainage verdict and the retailer row — not the ENERGY STAR primary.
  3. Judge how damp it is — honestly. Moderately damp is 50–75% RH (a musty smell that comes and goes); very damp is 75–90% (always smells damp, damp spots); wet is 90–100% (walls or floor sweat, seepage). A hygrometer settles it for a few dollars. If you are between two bands, take the wetter one.
  4. Check the temperature. Above 65°F a standard compressor unit works. At 55–65°F you need a low-temperature model with auto-defrost. Below 55°F a standard unit spends its time defrosting — you need a desiccant unit (works to −4°F / −20°C) or an LGR unit.
  5. Count the extra moisture sources. Laundry drying indoors, windows or doors often open, high traffic, cooking or showering nearby — each one adds 5 pints a day. A basement with laundry and an open stairwell is two sources, not none.
  6. Read the recommended size. The result shows the ENERGY STAR figure first — that is the number on the box of a unit sold today (2019 rating, 65°F test). The old-label equivalent is alongside it for comparing with an older unit or an old buying guide. Buy the next standard size at or above the figure: 20, 30, 35 or 50 pints.
  7. Compare the three methods — and trust the ENERGY STAR one. The AHAM cross-check reads far lower because it was drawn at 80°F; the retailer rule (1 pint per 50 sq ft) reads about 43% high at 1,000 sq ft. The page shows all three so you can see the disagreement instead of having it hidden from you.
  8. Check what it will actually collect. The label is a laboratory figure at 65°F and 60% RH. In a real basement at 65°F and 50% RH, expect 50–65% of the old-label rating — a 60-pint old-label machine collects about 30–39 pints a day. If that is not enough, the room is wetter than the band you picked.
  9. Check the running cost. The tool prices the unit at the ENERGY STAR v6.0 minimum efficiency for its size class, at your rate and your run hours. A 35-pint unit at 3 hours a day costs about $69 a year at the US average rate — a 24/7 unit in a wet basement costs eight times that, so the hours matter more than the watts.
  10. Plan the drainage before you buy. A basement or crawlspace unit fills a bucket in hours. A gravity drain hose works if a floor drain is near; otherwise you need a condensate pump, or a unit with a built-in pump. A bucket is fine in a living room — it is a chore in a basement.
  11. Set the humidistat to 45%. The healthy range is 30–50% RH; 45% is the practical target for a basement. Lower than 40% dries the air for no benefit and runs the unit longer; above 50% the musty smell comes back.
  12. Use the link. The page keeps your inputs in the address bar, so the Copy link button gives you a link that reopens the same room, dampness and temperature — useful for comparing two rooms, or for sending the numbers to your contractor.

Dehumidifier Size Calculator — What Size Do I Need? Pints Per Day formula

Floor area = length × width (or the floor area you enter directly — it replaces length × width)

ENERGY STAR primary (2019 rating), interpolated by area over 0–2,000 sq ft: moderately damp 20 → 30 pints · very damp 25 → 40 · wet 30 → 50 — linear from the low end at 0 sq ft to the high end at 2,000 sq ft, continuing linearly above 2,000 sq ft. (Very wet 35 → 60 and extremely wet 40 → 70 continue the table's step pattern and are this page's labelled extension.)

Ceiling correction: × ceiling height ÷ 8, only above 8 ft

Extra moisture sources: +5 pints each (laundry, windows/doors, high traffic, cooking/showering)

Primary = the interpolated figure × ceiling correction + 5 × sources, rounded UP to the next 5 pints

Recommended = the larger of the primary and your measured collection, rounded up to the next 5 pints — a measurement raises the answer, never lowers it

AHAM cross-check (old 80°F scale): pints = base + rate × area, with base 6 → 10 and rate 0.008 → 0.016 across the five dampness bands (moderate 6 + 0.008 × area … extremely wet 10 + 0.016 × area)

Old ↔ new conversion (ENERGY STAR table, piecewise-linear): old 30 → new 20 · 40 → 25 · 50 → 30 · 60 → 35 · 70 → 40–45 · 90 → 55. Below 30 old, use slope 20/30; above 90 old, slope 55/90. Never a flat 0.70.

Old-label equivalent = the conversion table inverted: new 20 → old 30 · 25 → 40 · 30 → 50 · 35 → 60 · 42.5 → 70 · 55 → 90

Retailer method (shown to expose its bias): area ÷ 50 × dampness correction (moderate ×1.0, very damp ×1.25, wet ×1.5, water damage ×2) × basement/crawlspace ×1.125 × ceiling height ÷ 8 if over 8 ft

Next standard size: the smallest of 20 / 30 / 35 / 50 pints at or above the recommended figure — above 50 pints, the room needs a whole-basement or ducted whole-home unit

Real-world extraction at 65°F / 50% RH = 50–65% of the old-label rating

Annual kWh = rated pints/day × 0.4732 L/pint ÷ 24 h × run hours/day × 365 ÷ IEF — IEF is the ENERGY STAR v6.0 minimum for the size class (≤25 pints: 1.70 · 25.01–50: 2.01 · ≥50: 3.30 L/kWh; federal minimums 1.30 / 1.60 / 2.80). Cost = kWh × your rate. The default 3 hours a day is the DOE's 1,095 operating hours a year.

1 US pint = 0.4732 L · 1 m² = 10.764 sq ft. The 2019 test conditions are 65°F / 60% RH for portables and 73°F / 60% RH for whole-home units (10 CFR 430 App. X1, since June 13, 2019); the old test was 80°F / 60% RH, which is why the same machine carries a smaller number on today's box.

Worked example

Worked example — 1,000 sq ft basement, very damp, 8 ft ceiling, no extra moisture sources. This is the tool’s default, worked by hand so you can check it.

  1. Floor area: 25 × 40 = 1,000 sq ft (92.9 m²).
  2. ENERGY STAR band: very damp is 25–40 pints over 0–2,000 sq ft. At 1,000 sq ft — halfway up the band — the interpolated figure is 25 + 15 × (1,000 ÷ 2,000) = 32.5 pints.
  3. Ceiling correction: the ceiling is 8 ft, so there is none (×1.0).
  4. Extra moisture sources: none, so +0 pints.
  5. Primary: 32.5 pints, rounded up to the next 5 = 35 pints (2019 rating) — 16.6 L/day. No basement uplift is applied to the primary; it lives in the retailer row below.
  6. Old-label equivalent: invert the ENERGY STAR table — 35 new is ≈ 60 pints on the pre-2019 label. A 60-pint unit from before 2019 is the same machine as a 35-pint unit today.
  7. Size to buy: the next standard size at or above 35 pints is a 35-pint unit — or a 50-pint one for headroom. Present it as “buy 35–50”.
  8. AHAM cross-check: very damp fit = 7 + 0.010 × 1,000 = 17 pints on the old 80°F scale → converted with the ENERGY STAR table (17 × 20 ÷ 30) ≈ 12 pints new. It reads far lower because it was drawn at 80°F; the ENERGY STAR figure governs.
  9. Retailer method: 1,000 ÷ 50 = 20 × 1.25 (very damp) × 1.125 (basement) = ≈ 28 pints (AHAM scale). Shown to expose the bias, not to size by.
  10. What it will actually collect: 50–65% of the old-label 60 pints = 30–39 pints a day in a real basement at 65°F / 50% RH.
  11. Running cost: 35 pints × 0.4732 L/pint ÷ 24 h × 3 h/day × 365 ÷ 2.01 L/kWh (ENERGY STAR v6.0 minimum for the 25–50 pint class) = 375.9 kWh/year × $0.1831/kWh (EIA, July 2026 US average) = $68.83/year — about $69/year ($5.74/month).
  12. Temperature and drainage: a basement at 65°F or above takes a standard compressor unit; below 65°F it needs a low-temperature model with auto-defrost. A basement needs continuous drainage — a gravity hose if a floor drain is near, otherwise a condensate pump. Set the humidistat to 45% RH.

Metric twin — 93 m² (≈1,000 sq ft), same inputs. 93 m² is 1,001 sq ft, so the interpolated figure is 32.5 pints and the answer is the same: 35 pints = 16.6 L/day, old-label ≈ 60, buy 35–50, running cost $69/year at 18.31¢/kWh.

Same basement, 10 ft ceiling. The ceiling correction is 10 ÷ 8 = 1.25, so 32.5 × 1.25 = 40.6 → rounded up to the next 5 = 45 pints. Buy a 50-pint unit. Two feet of ceiling costs a whole size.

Same basement, laundry drying indoors as well. One extra source is +5 pints: 32.5 + 5 = 37.5 → 40 pints, so buy a 50-pint unit.

Small room — 500 sq ft, moderately damp. The band is 20–30, so at 500 sq ft the figure is 22.5 → 25 pints. The AHAM cross-check is 10 pints old ≈ 7 new, and the retailer rule gives 10 pints — the three methods agree only at the bottom of the chart.

Dehumidifier tables: ENERGY STAR, AHAM, conversions, costs and cold rooms

Why three methods disagree — read this before you buy. The same 1,000 sq ft moderately damp room reads ≈10 pints new on the AHAM chart, ≈20 pints (AHAM scale) on the retailer rule, and ≈25 pints new on the ENERGY STAR chart — a 2.5× spread for one room. The AHAM chart was drawn at 80°F, so its pints are the biggest; the retailer rule is a flat 1 pint per 50 sq ft with no test condition behind it; the ENERGY STAR chart is the current 65°F rating, and it is the one this tool sizes by. The other two are shown so you can see the disagreement, not so you can average them.

The flat 0.70 conversion is wrong. Several calculators convert old pints to new by multiplying by 0.70 — miniwebtool does exactly this. The ENERGY STAR table's real ratios run from 0.58 to 0.67 (20/30 = 0.67, 25/40 = 0.63, 30/50 = 0.60, 35/60 = 0.58, 42.5/70 = 0.61, 55/90 = 0.61). And “70 old ≈ 50 new” — the figure the 0.70 rule gives — is wrong: the ENERGY STAR table says 40–45. This page converts with the table, never with a flat factor.

The flat “1 pint per 50 sq ft” rule runs about 43% high. At 1,000 sq ft it gives 20 pints where the AHAM chart gives 14 — 20 ÷ 14 = 1.43. It is a retailer rule of thumb, not a standard, and it ignores dampness, ceiling height and temperature entirely until the corrections are bolted on. Use it as a cross-check, never as the size.

The ENERGY STAR range is coarse — the interpolation is this page's labelled method. ENERGY STAR publishes a range for a whole band of room sizes (20–30 pints for any moderately damp space under 2,000 sq ft). This page interpolates linearly inside the band, so a 500 sq ft room reads lower than a 1,500 sq ft room in the same band. That is a choice, and it is named here — the alternative (take the top of the range for every room) would oversize every small room.

Ratings are at 65°F, your room is not a laboratory. The 2019 rating is measured at 65°F and 60% RH; the old rating at 80°F and 60% RH. A colder or drier room collects less — expect 50–65% of the old-label rating in a real 65°F basement at 50% RH, and less again below 60°F. Real-world extraction runs 30–50% below the label, and a unit that never reaches its setpoint is undersized, whatever the box says.

Water coming through the walls or floor needs a drainage fix, not a bigger unit. A dehumidifier dries air; it does not stop water. Seepage, a high water table, failed grading or a leaking pipe will keep any portable unit running flat out. Fix the water first, then size the unit for the residual humidity.

ENERGY STAR sizing chart (current, 2019 rating). The ranges are for the space before dehumidification; over 2,000 sq ft the chart gives floors, not ranges.

Condition without a dehumidifierRelative humidityUnder 2,000 sq ftOver 2,000 sq ft
Slightly to moderately damp — feels damp, musty smell that comes and goes50–75%20–30 pints/day30+ pints/day
Very damp — always smells damp, damp spots on walls and floors75–90%25–40 pints/day40+ pints/day
Wet — walls or floor sweat, seepage, laundry drying indoors90–100%30–50 pints/day50+ pints/day

AHAM classic chart (reference only — old 80°F / 60% RH scale). Pints of water removed per 24 hours. To compare with a unit sold today, convert with the table below — never with a flat 0.70.

Dampness500 sq ft1,000 sq ft1,500 sq ft2,000 sq ft2,500 sq ft
Moderately damp (50–60% RH)1014182226
Very damp (60–70% RH)1217222732
Wet (70–80% RH)1420263238
Very wet (80–90% RH)1623303744
Extremely wet (90–100% RH)1826344250

Old ↔ new conversion (ENERGY STAR table). Old = the pre-2019 label (80°F test); new = the 2019 rating on units sold today (65°F test).

Old capacity ratingApproximate modern rating
30 pints/day20 pints/day
40 pints/day25 pints/day
50 pints/day30 pints/day
55 pints/day30–35 pints/day
60 pints/day35 pints/day
70 pints/day40–45 pints/day
90 pints/day55 pints/day

Size by room — both scales. ENERGY STAR primary (2019 rating, rounded up to the next 5 pints) against the AHAM cross-check (old scale, then converted). The gap between the two columns is the 80°F vs 65°F test — it is not an error.

RoomENERGY STAR (new)AHAM old → new
500 sq ft, moderately damp25 pints10 old → 7 new
500 sq ft, very damp30 pints12 old → 8 new
500 sq ft, wet35 pints14 old → 10 new
1,000 sq ft, moderately damp25 pints14 old → 10 new
1,000 sq ft, very damp35 pints17 old → 12 new
1,000 sq ft, wet40 pints20 old → 14 new
1,500 sq ft, moderately damp30 pints18 old → 12 new
1,500 sq ft, very damp40 pints22 old → 15 new
1,500 sq ft, wet45 pints26 old → 18 new
2,000 sq ft, moderately damp30 pints22 old → 15 new
2,000 sq ft, very damp40 pints27 old → 18 new
2,000 sq ft, wet50 pints32 old → 22 new

Running cost by size — at the ENERGY STAR v6.0 minimum IEF, 3 hours a day, 18.31¢/kWh (EIA, July 2026). A unit that runs 24/7 costs eight times these figures.

Size (2019 rating)Min IEF (L/kWh)kWh / yearCost / yearCost / month
20 pints1.70254.0$46.51$3.88
30 pints2.01322.2$59.00$4.92
35 pints2.01375.9$68.83$5.74
50 pints2.01537.1$98.34$8.19

Efficiency minimums by size class (L/kWh). The federal minimum is the legal floor; ENERGY STAR v6.0 (effective October 1, 2025) is the stricter bar this tool prices at. A unit that beats its class minimum costs less than the table above.

Portable capacityFederal minimum (10 CFR 430.32(v))ENERGY STAR v6.0 minimum
25 pints/day or less1.301.70
25.01–50 pints/day1.602.01
50 pints/day or more2.803.30

Temperature guidance — the type matters as much as the size.

Room temperatureWhat to buyWhy
Above 65°F (18°C)Standard compressor dehumidifierNormal conditions — the rating on the box applies
55–65°F (13–18°C)Low-temperature model with auto-defrostFrost risk below 65°F — a standard unit ices up and stops
Below 55°F (13°C)Desiccant or LGR unitLGR runs 10–15% better than a conventional unit in the cold; a desiccant unit works down to −4°F (−20°C)

Measurement tips

  • Buy on the 2019 number, not the old one. A unit sold today is rated at 65°F; a unit or a buying guide from before 2019 is rated at 80°F. A “70-pint” machine from 2018 is a “40–45 pint” machine today — same hardware, smaller number. Compare only within one scale, and let the tool convert.
  • Size up, not down — a little. ENERGY STAR says it is better to oversize than undersize, and the next standard size up is usually the right buy: a 35-pint need takes a 35-pint unit, or a 50-pint one for headroom. An undersized unit runs flat out, never reaches the setpoint, and still costs electricity.
  • Measure the dampness with a hygrometer. A few dollars buys the number the whole calculation turns on. Guessing “very damp” when the room is actually wet undersizes the unit by a whole band — and the musty smell stays.
  • Fix the water before you size the unit. Seepage, a high water table, failed grading, a leaking pipe or a dryer venting indoors will overwhelm any portable unit. A dehumidifier manages residual humidity; it is not a substitute for drainage, grading or a repair.
  • Plan the drain before you buy. A basement unit fills a bucket in hours and stops when it is full. A gravity hose to a floor drain is free to run; a condensate pump or a built-in pump costs more up front and never needs emptying. Decide which one before the unit arrives.
  • Set the humidistat to 45% and leave it. The healthy range is 30–50% RH; 45% is the practical basement target. Chasing 35% runs the unit far longer for no benefit, and above 50% the musty smell comes back.
  • Keep the space closed while it runs. Open windows and doors keep bringing damp outside air in — each one is +5 pints a day on this page. Close the space, let the unit pull the room down, and only then judge whether it is big enough.
  • Clean the filter and keep the airflow clear. A clogged filter or a unit pushed against the wall starves the coil and cuts extraction. The rating assumes clean air and the clearances in the manual.
  • Check the IEF, not just the pints. Two 50-pint units can cost very different amounts to run: at the ENERGY STAR v6.0 minimum (2.01 L/kWh) a 50-pint unit costs about $98 a year at 3 hours a day; a cheap non-certified unit at the federal minimum (1.60 L/kWh) costs about a quarter more for the same water. The efficiency label is the running-cost label.
  • Give it a week before you judge it. A wet basement holds moisture in the walls, floor and stored boxes — the first days pull water out of the materials, not just the air. Judge the unit on whether the room holds 45% RH after a week, not on the first bucket.

Common mistakes

  • Buying the old number. The most common error in dehumidifier sizing: a guide says 70 pints, so a 70-pint unit is bought — but the guide is pre-2019 and the box is 2019, so the buyer overshoots by half. Or the reverse: a 50-pint unit is bought to replace a 70-pint one, and the room stays damp. Match the scale before you match the number.
  • Using a flat 0.70 to convert old to new. It looks tidy and it is wrong: the ENERGY STAR table's ratios run 0.58–0.67, and 70 old is 40–45 new, not 50. A flat factor oversizes the small units and undersizes the big ones.
  • Trusting “1 pint per 50 sq ft”. The retailer rule gives 20 pints for a 1,000 sq ft room where the AHAM chart gives 14 — about 43% high — and it ignores dampness, ceiling height and temperature entirely. It is a sales rule, not a sizing standard.
  • Sizing by floor area alone. The same 1,000 sq ft room needs 25 pints moderately damp and 40 pints wet — nearly double for the same floor. Dampness is half the calculation; a square-footage-only chart is a coin toss.
  • Forgetting the ceiling. A 1,000 sq ft basement at 8 ft needs 35 pints very damp; at 10 ft it needs 45. Two feet of ceiling is a whole size — vaulted or tall basements are the quiet reason a “right-sized” unit under-performs.
  • Buying a standard unit for a cold basement. Below 65°F a standard compressor unit ices up; below 55°F it spends its time defrosting. A cold basement needs a low-temperature model with auto-defrost, and below 55°F a desiccant or LGR unit — the pints on the box assume 65°F.
  • Counting on the bucket. A basement unit fills a bucket in hours, and a full bucket stops the unit — usually overnight, when the humidity climbs back. If nobody is there to empty it, the unit is a part-time dehumidifier. Fit a drain hose or a pump.
  • Setting the humidistat to 30%. The healthy range is 30–50%, but 30% is the floor, not the target. Chasing it runs the unit far longer, costs more, and dries the air past the point of any benefit. Set 45% and leave it.
  • Expecting the label in a real room. The rating is measured at 65°F and 60% RH in a laboratory. In a real basement at 65°F and 50% RH, expect 50–65% of the old-label rating — a 60-pint old-label machine collects 30–39 pints a day. If the bucket is lighter than the label, the room is colder or drier than the test, not broken.
  • Buying a bigger unit instead of fixing the water. Seepage through a wall, a high water table or a leaking pipe will keep any portable unit running flat out. A bigger unit dries the air faster while the water keeps coming in — the fix is drainage, grading or a repair, and the dehumidifier comes after.

Factors that affect accuracy

  • Floor area — the ENERGY STAR band. The primary figure is interpolated inside the band for your exact area: moderately damp 20–30, very damp 25–40, wet 30–50 pints over 0–2,000 sq ft. A 500 sq ft room reads lower than a 1,500 sq ft room in the same band — the interpolation is this page's labelled method.
  • Dampness — the other half of the size. The same 1,000 sq ft room needs 25 pints moderately damp, 35 very damp and 40 wet. Dampness is judged by RH (50–75 / 75–90 / 90–100%) or by what you see — a hygrometer settles it for a few dollars.
  • Ceiling height — more air to dry. Above 8 ft the figure scales by height ÷ 8: a 10 ft ceiling adds 25%, a 12 ft ceiling adds 50%. The AHAM chart and the ENERGY STAR chart both assume a standard 8 ft ceiling.
  • Extra moisture sources — +5 pints each. Laundry drying indoors, windows or doors often open, high traffic, cooking or showering nearby. Each one is a steady stream of water into the air, and each one adds 5 pints a day.
  • Temperature — the type, not just the size. Above 65°F a standard compressor unit works; 55–65°F needs a low-temperature model with auto-defrost; below 55°F needs a desiccant unit (to −4°F / −20°C) or an LGR unit (10–15% better than conventional in the cold).
  • Space type — where the moisture comes from. Basements and crawlspaces take moisture through the ground, so the retailer row adds 10–15% for them; the ENERGY STAR primary does not. A whole-home space over 50 pints a day needs a ducted unit, not a bigger portable.
  • Measured collection — the ground truth. If you already own a unit, what it collects in 24 hours beats any chart. The tool takes the larger of the calculated figure and your measured collection, rounded up to the next 5 pints — a measurement raises the answer, never lowers it.
  • Air leakage — the invisible load. An open stairwell, an unsealed rim joist or a dryer venting indoors keeps bringing damp air in. The tool counts open windows and doors as +5 pints; a leaky basement envelope is the same load with no field to enter — seal what you can before you size.
  • Efficiency (IEF) — the running cost. The Integrated Energy Factor is litres removed per kWh: higher is cheaper to run. The ENERGY STAR v6.0 minimums are 1.70 / 2.01 / 3.30 L/kWh by size class, against federal minimums of 1.30 / 1.60 / 2.80. A unit that beats its class minimum costs less than the table on this page.
  • Run hours — the cost lever. The default is 3 hours a day (the DOE's 1,095 operating hours a year). A wet basement unit that runs 24/7 costs eight times the table figure — the hours matter more than the watts, and the humidistat is what controls them.

Sources & assumptions

  • Method — ENERGY STAR's sizing chart (Dehumidifiers, Buying Guidance; specification effective October 1, 2025): under 2,000 sq ft, 20–30 pints a day for a slightly to moderately damp space (50–75% RH), 25–40 for a very damp one (75–90%), 30–50 for a wet one (90–100%); over 2,000 sq ft, 30+, 40+ and 50+ pints. Confirmed 2026-11-17 against QuietTechReport's dehumidifier size calculator, HVACBase's dehumidifier guide and AlorAir's sizing guide, all of which reproduce the same chart and RH bands. This page interpolates linearly inside the band by exact area (a labelled method — the chart itself gives only ranges), continues linearly above 2,000 sq ft, then applies the ceiling correction (× height ÷ 8 above 8 ft) and +5 pints per extra moisture source, and rounds up to the next 5 pints.
  • The two wettest bands are this page's extension, not ENERGY STAR's table: very wet 35–60 and extremely wet 40–70 pints over 0–2,000 sq ft continue the published table's own step pattern (+5 at the low end, +10 at the high end per band). The page labels them as such and treats them as a floor — standing water is a drainage job first, not a bigger unit.
  • AHAM cross-check — the classic AHAM Dehumidification Selection Guide (reproduced by Cornell Cooperative Extension): pints per 24 hours on the old 80°F / 60% RH scale. At 1,000 sq ft: moderately damp 14, very damp 17, wet 20, very wet 23, extremely wet 26 pints. The fits this page uses — moderate 6 + 0.008 × area through extremely wet 10 + 0.016 × area, middle bands interpolated — reproduce the chart exactly at every 500 sq ft step, confirmed 2026-11-17 against MiniWebTool's dehumidifier size calculator (which states the same two endpoint fits) and NRTechStudio's AHAM table.
  • Old ↔ new conversion — ENERGY STAR's conversion table (Dehumidifier Testing and Capacity): old 30 → new 20, 40 → 25, 50 → 30, 55 → 30–35, 60 → 35, 70 → 40–45, 90 → 55. Confirmed 2026-11-17 against QuietTechReport (full table reproduced) and HVACBase (70 → 40–45). This page converts piecewise-linearly through (30,20),(40,25),(50,30),(60,35),(70,42.5),(90,55), with slope 20/30 below 30 and 55/90 above 90 — never a flat 0.70. The table's real ratios are 0.58–0.67, and '70 old ≈ 50 new' (the 0.70 rule's answer, quoted by NRTechStudio) is wrong against the table — the page says so. At 70 old the page shows the range 40–45, not a single figure.
  • Retailer method row — USCleaningTools' dehumidifier size calculator: flat 1 pint per 50 sq ft × dampness correction (moderate ×1.0, very damp ×1.25, wet ×1.5, water damage ×2) × basement/crawl ×1.125 × ceiling height ÷ 8 if over 8 ft. Shown on the page to expose its bias: at 1,000 sq ft it gives 20 pints where the AHAM chart gives 14 — about 43% high. The very-wet ×1.75 correction is this page's interpolation between wet ×1.5 and water damage ×2.
  • Efficiency — Integrated Energy Factor (IEF), litres removed per kWh. Federal minimums (10 CFR 430.32(v), for dehumidifiers manufactured on or after June 13, 2019): ≤25 pints/day 1.30, 25.01–50 1.60, ≥50.01 2.80 L/kWh — confirmed 2026-11-17 against Natural Resources Canada's DOE standards table and the May 16, 2025 Federal Register notice (which also records the DOE proposal to rescind the amended standards — a proposal, not a final rule, so the page states the current standards). ENERGY STAR v6.0 minimums (effective October 1, 2025): 1.70 / 2.01 / 3.30 on the same classes — confirmed against ENERGY STAR's Key Efficiency Criteria. This tool prices running cost at the v6.0 minimum for the size class.
  • Running cost — annual kWh = (rated pints/day × 0.4732 L/pint ÷ 24 h × run hours/day × 365) ÷ IEF. The default 3 hours a day is the DOE's 1,095 operating hours a year, confirmed 2026-11-17 against the ENERGY STAR v6.0 specification and the DOE 2023 test-procedure final rule (via WattCost's running-cost guide). The default rate is the US average residential price, 18.31 cents per kWh (EIA, July 2026, Electric Power Monthly Table 5.6.A — confirmed against multiple EIA-derived reports).
  • Test conditions — the 2019 DOE test (10 CFR 430 App. X1, since June 13, 2019) rates portables at 65°F / 60% RH and whole-home units at 73°F / 60% RH; the old test was 80°F / 60% RH, which is why the same machine carries a smaller number on today's box. Real-world extraction runs 30–50% below the label depending on temperature and humidity (USCleaningTools), and this page shows 50–65% of the old-label rating at 65°F / 50% RH.
  • Temperature — frost becomes a risk below 65°F (ENERGY STAR). Below 55°F a standard compressor unit spends its time defrosting: use a desiccant unit, which works down to −4°F (−20°C) (confirmed against Sylvane's desiccant vs refrigerant guide and CtrlTech), or an LGR (low-grain refrigerant) unit, which runs 10–15% better than a conventional unit in the cold and works down to about 40°F (USCleaningTools; EngineerFix).
  • Water damage — the IICRC S500 standard sizes restoration drying by room volume ÷ class factor (Class 1 ÷100, Class 2 ÷50, Class 3 ÷40); the common restoration rule of thumb is one LGR dehumidifier per 1,000 sq ft for active water damage (USCleaningTools). This page labels the rule of thumb as such and does not size restoration jobs — they need a contractor.
  • Setpoint — the EPA recommends keeping indoor relative humidity between 30% and 50%, and always below 60%; this page targets 45% RH for a basement. 1 US pint = 0.4732 L; 1 m² = 10.7639 sq ft.
  • Canonical example (this tool): 1,000 sq ft basement, very damp, 8 ft ceiling, no extra sources — ENERGY STAR band 25–40 → interpolated 32.5 → primary 35 pints (2019) = 16.6 L/day; old-label ≈ 60; buy 35 (or 50 for headroom); AHAM 17 old ≈ 12 new; retailer method 20 × 1.25 × 1.125 = 28.1 ≈ 28 AHAM pints; real-world 30–39 pints/day at 65°F/50% RH; running cost 375.9 kWh/year at IEF 2.01, 3 h/day, 18.31¢/kWh = $68.83/year ($5.74/month). Metric twin: 93 m² (~1,000 sq ft) same inputs → 35 pints = 16.6 L/day. Same basement at a 10 ft ceiling: 32.5 × 1.25 = 40.6 → 45 pints, buy 50. With laundry drying indoors as well: 32.5 + 5 = 37.5 → 40 pints, buy 50.

Figures checked on 28 November 2026 as part of the site-wide test run (3239 automated checks, all passing). See how we calculate and test.

Please note: material estimates are approximate. Always confirm product coverage with the manufacturer and buy a little extra for cuts, waste and future repairs.

What this calculator doesn't do

  • This is a sizing estimate, not a drying design. It follows ENERGY STAR's published sizing chart and the AHAM selection chart, but it does not measure your air leakage, your groundwater, or the moisture stored in wet materials. A basement that takes water through the walls or floor needs a drainage fix first — a bigger dehumidifier dries the air while the water keeps coming in.
  • It sizes portable dehumidifiers for homes, not commercial or restoration drying. Water-damage restoration is sized by the IICRC S500 method — room volume divided by a class factor (Class 1 ÷100, Class 2 ÷50, Class 3 ÷40) — with a common rule of thumb of one LGR unit per 1,000 sq ft. If you are drying a flood or a burst pipe, hire a restoration contractor; this tool's figure is a minimum, not a drying plan.
  • It does not size grow rooms, pool rooms, or commercial spaces. A room full of plants, a laundry that runs all day, or an indoor pool releases water by the litre, and the right size comes from the water going in — not from the floor area. This tool has no grow-room or commercial mode.
  • The two wettest dampness bands are this page's extension, not ENERGY STAR's table. ENERGY STAR publishes three bands (moderately damp, very damp, wet); the very wet and extremely wet bands continue the table's own step pattern and are labelled as such. Treat them as a floor, not a guarantee — and for standing water, fix the water first.
  • The running cost assumes the unit runs at full capacity for the hours you enter, at the ENERGY STAR v6.0 minimum efficiency for its size class. A real unit cycles on its humidistat, and a cheap non-certified unit can cost far more — the cost is a planning figure at the minimum efficiency, not a quote from your bill.
  • This version sizes in US pints per day (the 2019 DOE rating, 65°F test) with litres per day alongside. A UK mode is not built yet — the results show the L/day equivalent of every pints figure (1 US pint = 0.4732 L) so you can shop either way.

Dehumidifier Size Calculator — What Size Do I Need? Pints Per Day — frequently asked questions

What size dehumidifier do I need?

A 1,000 sq ft very damp basement with an 8 ft ceiling needs a 35-pint dehumidifier (2019 rating) — buy a 35-pint unit, or a 50-pint one for headroom. A 500 sq ft moderately damp room needs only 25 pints, and a 1,000 sq ft wet basement needs 40 pints. Anything over 50 pints a day needs a whole-basement or ducted unit. Use the calculator above with your room, dampness and ceiling height for your exact figure.

How many pints per day do I need for a 1,000 sq ft basement?

35 pints a day if it is very damp, 25 if it is only moderately damp, 40 if it is wet — all on the 2019 rating, the number on the box of a unit sold today. The ENERGY STAR band for very damp is 25–40 pints, and 1,000 sq ft sits halfway up it, so the interpolated figure is 32.5 pints, rounded up to 35. The same room reads 17 pints on the old AHAM chart (80°F test) — about 12 pints new — which is why old guides look so much smaller.

How many pints do I need for a 500 sq ft room?

25 pints if it is moderately damp, 30 if very damp, 35 if wet (2019 rating). The ENERGY STAR band for moderately damp is 20–30 pints, and at 500 sq ft the interpolated figure is 22.5 pints, rounded up to 25. The AHAM cross-check is 10 pints on the old 80°F scale (about 7 new) — the two charts disagree because they were drawn at different temperatures, and the ENERGY STAR figure is the one to buy by.

What size dehumidifier do I need for a 2,000 sq ft basement?

30 pints moderately damp, 40 very damp, 50 wet — the top of the ENERGY STAR bands. Above 2,000 sq ft the chart gives floors, not ranges: 30+ pints moderately damp, 40+ very damp, 50+ wet, and the figure keeps rising linearly with area. A 2,500 sq ft very damp basement needs 45 pints, and a 2,500 sq ft wet one needs 55 pints — above the largest portable size, so that room needs a whole-basement or ducted unit.

How do I calculate dehumidifier size?

Take the ENERGY STAR band for your dampness and interpolate by area. Moderately damp is 20–30 pints, very damp 25–40, wet 30–50 over 0–2,000 sq ft — a 1,000 sq ft very damp room sits halfway up its band at 32.5 pints. Then multiply by ceiling height ÷ 8 if the ceiling is over 8 ft, add 5 pints per extra moisture source (laundry, open windows, high traffic, cooking), and round up to the next 5 pints. That is the 2019-rating figure to buy by — the calculator above does all of it, and shows the AHAM and retailer figures alongside so you can see why they differ.

What is the difference between old and new pint ratings?

The test got colder. Before 2019, dehumidifiers were rated at 80°F and 60% RH; since June 2019 the DOE tests portables at 65°F and 60% RH (10 CFR 430 App. X1), and cooler air holds less moisture — so the same machine carries a smaller number today. ENERGY STAR's conversion table: old 30 → new 20, 40 → 25, 50 → 30, 60 → 35, 70 → 40–45, 90 → 55. A “70-pint” unit from 2018 is a “40–45 pint” unit today. Never convert with a flat 0.70 — the table's real ratios are 0.58–0.67.

How much does it cost to run a dehumidifier?

About $69 a year for a 35-pint unit at 3 hours a day — 375.9 kWh a year at the ENERGY STAR v6.0 minimum efficiency (2.01 L/kWh), priced at 18.31 cents/kWh (EIA, July 2026 US average). A 20-pint unit costs about $47 a year, a 30-pint about $59, a 50-pint about $98. A unit that runs 24/7 costs eight times these figures, so the run hours — set by the humidistat — matter more than the watts. Enter your own rate and hours above for your exact cost, in any currency.

Do I need a desiccant dehumidifier for a cold basement?

Below 55°F, yes — a desiccant or LGR unit. A standard compressor dehumidifier ices up below 65°F, so a cool basement at 55–65°F needs a low-temperature model with auto-defrost, and below 55°F a standard unit spends its time defrosting instead of drying. An LGR (low-grain refrigerant) unit runs about 10–15% better than a conventional one in the cold; a desiccant unit works by adsorption, not condensation, so it keeps working down to −4°F (−20°C). Above 65°F a standard compressor unit is the efficient choice.

How many litres per day is a 35-pint dehumidifier? (metric)

35 pints is 16.6 litres per day. The conversion is litres = pints × 0.4732, so 20 pints is 9.5 L/day, 30 pints is 14.2 L/day, 35 pints is 16.6 L/day and 50 pints is 23.7 L/day. A 93 m² basement (≈1,000 sq ft), very damp, needs the same 35 pints = 16.6 L/day as the 1,000 sq ft worked example. European units are rated in litres per day at warmer test conditions, so their numbers look larger — always check the stated test condition before comparing.

What size dehumidifier do I need for a metric room?

Work in square feet for the ENERGY STAR method, then convert. A 9 × 10 m basement is 90 m², which is 969 sq ft (1 m² = 10.764 sq ft), so a very damp one interpolates to 32.3 pints — the tool rounds the requirement up to 35 pints (16.6 L/day), old-label ≈ 60, buy 35–50. With a 3 m ceiling the correction is 3 ÷ 2.44 = 1.23, so 32.3 × 1.23 = 39.7 → 40 pints, and you buy a 50-pint unit. A 46 m² room (≈500 sq ft), moderately damp, needs 25 pints (11.8 L/day).

Next step

Take the recommended pints, the old-label equivalent and the temperature verdict to the store — and check the IEF on the exact model's spec sheet before you buy, because the running cost on this page is priced at the ENERGY STAR v6.0 minimum for the size class, and a cheaper non-certified unit can cost a quarter more to run. Then plan the drainage with the bathroom fan size calculator if the damp is in a bathroom, and check the room's insulation with the insulation calculator — a cold basement wall condenses moisture no dehumidifier can fix.

Save this estimate: use the Copy link button in the results box above to share these exact inputs, or Print results for a paper copy to take to the store.