Framing Calculator
A wall is not just length divided by spacing. The spacing layout gives you the field studs, and then every corner, every door and every window adds studs the layout never sees — kings, jacks and cripples — and the plates run the full length two or three times over. This framing calculator takes the wall in feet or metres and gives every piece separately, never a single unexplained total: field studs, corner studs, king studs, jack studs and sill cripples, each with its own count; bottom and top plate lengths for a single or double top plate; stud cut length (wall height minus the plate stack); total lumber in linear feet, metres and board feet; header pieces per opening; and a lumber cost from your own per-stud and per-plate-foot prices. For the sheets that cover the frame, use the drywall calculator; for insulation between the studs, the insulation calculator; and for board feet on any other lumber, the lumber calculator. Framing the stair opening too? The stair calculator — risers and treads works out the stair geometry the stringers are cut to.
Planning this project? Save to Pinterest to find this calculator again later.
How to use the Framing Calculator
- Measure the wall end to end for length and floor to underside of the top plate for height, in feet or metres. If you are framing a room, run the tool once per wall and add the four results — and count each corner once across the four runs, not once per wall, or every corner will be double-counted.
- Pick the spacing by what the wall carries, not by habit: 16 in OC for load-bearing walls, 24 in OC only for non-load-bearing partitions, walls carrying just a roof/ceiling, or advanced framing with 2x6 studs. Pick the stud size the same way: 2x4 is standard, 2x6 for taller walls, heavier loads and deeper insulation.
- Enter the corners on this wall, then the door and window counts. Read the breakdown, not just the total: field studs, corner extras, kings, jacks and sill cripples are shown separately, so a count that looks high can be traced to the opening or corner that caused it.
- Check the plate option. Double top plate is the default and the right choice for nearly every wall; single top plate is a code exception that needs steel ties at every joint, corner and intersection and joists or rafters centred within 1 in of the studs — if those conditions are not met, stay with double.
- Read the stud cut length (wall height minus the plate stack) before ordering: an 8 ft wall with a double top plate takes 91.5 in studs, and the store-bought precut equivalent is 92-5/8 in. Do not order full 8 ft studs for an 8 ft wall — they are longer than the space between the plates.
- Set the waste allowance by the lumber, not by optimism: 10% default, 15% for unsorted yard lumber or many openings. The buy count is the total rounded up after waste — that is the number to order, and the spares are your cripples and replacements, not over-ordering.
- Enter your per-stud and per-plate-foot prices for a lumber cost. The cost covers studs and plates only: headers are pieces, not priced here, and sheathing, drywall, insulation, nails, bracing and hold-downs are separate orders priced with the drywall, insulation and lumber calculators.
- Take the breakdown to the yard: buy studs by the buy count, plates by the buy length in the longest lengths that keep top-plate joints offset at least 24 in, and headers as 2-ply pieces per opening cut to each rough opening width and sized from the IRC header tables.
Framing Calculator formula
Worked example
A 12 ft long x 8 ft high wall, 16 in OC, 2x4 studs, double top plate, with 2 corners, 1 door and 1 window, at 10% waste. Step one — field studs: ceil(144 in / 16 in) + 1 = 9 + 1 = 10. Step two — extras: corners 2 x 2 = 4; openings 2 x 2 kings = 4 and 2 x 2 jacks = 4; window sill cripples 1 x 2 = 2. Step three — total: 10 + 4 + 4 + 4 + 2 = 24 studs before waste, ceil(24 x 1.10) = 27 studs to buy. Step four — stud length: 96 in - 4.5 in plate stack (1.5 in bottom + 3 in double top) = 91.5 in (7.625 ft / 2.324 m) each; the precut store equivalent is 92-5/8 in. Step five — plates: 12 ft x 3 runs (1 bottom + 2 top) = 36 ft net, 39.60 ft to buy at 10% waste. Step six — lumber: studs 27 x 7.625 = 205.88 ft + plates 39.60 ft = 245.48 linear ft (74.82 m); board feet 27 x 5.08 = 137.25 + 39.60 x 0.67 = 26.40 = 163.65 BF. Headers: 4 pieces (2-ply per opening x 2 openings), cut to each rough opening width and sized from the IRC header tables. Step seven — cost at $4 per stud and $1.20 per plate-foot: 27 x $4 = $108.00 + 39.60 x $1.20 = $47.52 = $155.52 for studs and plates.
Spacing version: the same 12 ft wall with no corners and no openings needs 10 field studs at 16 in OC but only 7 at 24 in OC (ceil(144 / 24) + 1) — 3 fewer studs, but 24 in OC is only for non-load-bearing walls, roof/ceiling-only walls or advanced framing with 2x6 studs, never as a saving on a load-bearing wall. Single-top version: the same wall with a single top plate needs 24 ft of plate instead of 36 ft and 93 in studs instead of 91.5 in — and steel ties at every joint, corner and intersection, with joists centred within 1 in of the studs.
Metric version: a 4 m long x 2.4 m high wall, 16 in (406 mm) OC, 2x4 studs, double top plate, with 1 door, no corners, no windows, at 10% waste. Length 4 m = 157.48 in; field = ceil(157.48 / 16) + 1 = 10 + 1 = 11; door kings 2 + jacks 2 = 4; total 15, buy ceil(15 x 1.10) = 17 studs. Stud length: 2.4 m (94.49 in) - 4.5 in plate stack = 89.99 in = 2.286 m each. Plates: 4 m x 3 runs = 12 m net, 13.20 m to buy. Lumber: studs 17 x 2.286 = 38.86 m + plates 13.20 m = 52.06 m (170.79 ft); board feet 84.99 + 28.87 = 113.86 BF. At 24 in (610 mm) OC the same wall needs field = ceil(157.48 / 24) + 1 = 7 + 1 = 8 studs, total 12, buy 14 — again, only where 24 in OC is permitted.
Field studs by wall length (before corners and openings):
| Wall length | At 16 in OC | At 24 in OC | Studs saved at 24 in OC |
|---|---|---|---|
| 8 ft (2.44 m) | 7 | 5 | 2 |
| 10 ft (3.05 m) | 9 | 6 | 3 |
| 12 ft (3.66 m) | 10 | 7 | 3 |
| 16 ft (4.88 m) | 13 | 9 | 4 |
| 20 ft (6.10 m) | 16 | 11 | 5 |
| 24 ft (7.32 m) | 19 | 13 | 6 |
Stud size and height limits (IRC Table R602.3(5), one floor plus roof/ceiling):
| Stud size | Actual size | Max height at 16 in OC | Max height at 24 in OC |
|---|---|---|---|
| 2x4 | 1.5 x 3.5 in (38 x 89 mm) | 10 ft (3.05 m) | 8 ft (2.44 m) |
| 2x6 | 1.5 x 5.5 in (38 x 140 mm) | 14 ft (4.27 m) | 12 ft (3.66 m) |
Measurement tips
- Read the breakdown, not just the total. A stud count that looks high is usually one window or one corner you forgot you entered — field, corner, king, jack and cripple counts are shown separately so the cause is visible.
- Count each corner once across the whole room. Running the tool per wall and entering 2 corners on every wall double-counts all four corners; give each corner to one wall only and the four runs will add up correctly.
- Use ceil(length / spacing) + 1, not length / spacing, for the field count. A wall whose length is not an exact multiple of the spacing still needs a stud at the far end — 10 ft at 16 in OC is 9 studs, not 8, because the last 8 in bay still ends in a stud.
- Order the buy count, not the exact count. The waste allowance is not padding for the sake of it: it is the crooked, bowed and split studs you will cull, the cripples you will cut from offcuts, and the plate joints you will offset.
- Buy plates in lengths that keep double-top-plate joints offset at least 24 in, and never stack a joint in the top plate directly over a joint in the bottom plate. The tool gives continuous feet; the yard gives fixed lengths — the waste allowance covers the offcuts.
- Check the stud cut length before ordering, not after delivery. An 8 ft wall with a double top plate takes 91.5 in studs (92-5/8 in precut); full 8 ft studs will not fit between the plates and will have to be cut on site.
- Keep 24 in OC for walls that are allowed it. The saving is real — 3 fewer studs on a 12 ft wall, 6 fewer on a 24 ft wall — but a load-bearing wall framed at 24 in OC to save lumber is a code failure, not a saving, and drywall on 24 in OC flexes more and needs 5/8 in sheets to stay flat.
- Sight down every stud before it goes in the wall. Crown (bow) all studs the same way so the wall face stays flat, and cull the worst pieces to cripples, blocking and fire blocking instead of forcing them into the layout.
- Size headers from the IRC header tables, never from the stud count. The tool counts header pieces; the tables decide whether that header is a double 2x8, a double 2x10 or an engineered beam — and whether it needs one jack or two per side.
Common mistakes
- Dividing length by spacing and stopping there. That gives the field studs only: on a 12 ft wall with 2 corners, 1 door and 1 window the field count is 10 but the real count is 24 — the corners and openings more than double it.
- Using floor(length / spacing) + 1 instead of ceil + 1. On any wall whose length is not an exact multiple of the spacing, the floor formula drops the far-end stud: 10 ft at 16 in OC gives 8 instead of 9, and the wall ends one stud short.
- Forgetting that a 2x4 is not 2 in by 4 in. Actual size is 1.5 x 3.5 in (38 x 89 mm); a 2x6 is 1.5 x 5.5 in. Wall thickness, drywall backing, door jamb width and insulation depth all follow the actual size, not the name.
- Framing a load-bearing wall at 24 in OC to save lumber. 24 in OC is permitted for non-load-bearing partitions, roof/ceiling-only walls and advanced framing with 2x6 studs — on a load-bearing wall the standard is 16 in OC, and the IRC height limits tighten at 24 in OC (a 2x4 drops from 10 ft to 8 ft).
- Counting only one king or one jack per opening instead of one per side. Each opening needs a king and a jack on EACH side — 2 kings and 2 jacks per opening, 4 pieces before cripples — and wide openings need a second jack per side on top of that.
- Ordering full-height studs. Studs are cut shorter than the wall height by the plate stack: 91.5 in for an 8 ft wall with a double top plate, 93 in with a single top plate. Full 8 ft studs do not fit and get cut on site, wasting the length you paid for.
- Using a single top plate without meeting the exception. A single top plate needs steel ties at every joint, corner and intersection AND joists or rafters centred within 1 in of the studs. Without both conditions, the wall needs the double top plate — the saving is one run of plate, the risk is the whole load path.
- Counting a corner on every wall that meets there. A room has four corners, not eight: run the tool per wall, assign each corner to one wall, and add the runs. Double-counted corners are the commonest reason a four-wall order comes in 8 studs high.
- Ordering at 0% waste. Framing lumber is not furniture-grade stock: crowns, bows, splits and plate-joint offcuts consume material on every wall, and a short order stops the job while one more stud is fetched.
- Sizing a header by guesswork. Header size follows the opening width and the load above it in the IRC tables; a header that is too small sags and cracks the finishes above it, and this tool deliberately does not size headers for that reason.
Factors that affect accuracy
- Wall length and spacing: the field count is ceil(length / spacing) + 1, so a wall just over a multiple of the spacing costs a whole extra stud — a 16 ft 1 in wall at 16 in OC needs 14 field studs, not 13.
- Load-bearing vs non-load-bearing: load-bearing walls default to 16 in OC; only non-load-bearing partitions, roof/ceiling-only walls and engineered advanced framing may use 24 in OC, and the height limits tighten at the wider spacing.
- Stud size: 2x6 studs cost more per piece and more board feet, but carry taller walls (14 ft at 16 in OC vs 10 ft for 2x4) and leave a deeper cavity for insulation — the choice is structural and thermal, not just price.
- Corners: each corner adds 2 studs beyond the field count, and the corner detail chosen (3-stud, California/Ladder, or two-stud with clips) changes the count and the insulation space inside the corner.
- Openings: each door or window adds 4 studs (2 king + 2 jack) plus 2 sill cripples per window, and wide openings add a second jack per side — a wall with many openings can need more opening studs than field studs.
- Top plate choice: a double top plate doubles the top-plate lumber and shortens every stud by 1.5 in against a single top plate, but it is the code default and the tie that locks intersecting walls together.
- Wall height: height sets the stud cut length and therefore the board feet and the price per stud, and it sets which stud size and spacing the IRC table allows — height, size and spacing are one decision, not three.
- Lumber quality and waste: unsorted yard lumber needs the 15% waste band for culling; pre-sorted or finger-jointed studs can run at 5-10%. The waste figure is a property of the lumber delivered, not of the wall.
- Plate lengths available: yards sell fixed lengths, so the continuous plate feet on this page become whole boards with joints — joints must be offset at least 24 in in a double top plate, and the offcuts land in the waste allowance.
Sources & assumptions
- Spacing standard and permitted alternative: 16 in on centre is the standard for load-bearing walls (IRC R602.3 / Table R602.3(5)) — per Jaspector's IRC 2024 stud-spacing summary (16 in OC the standard for most applications; 24 in OC permitted for the top story or single-story structures when wall height, load and stud size meet Table R602.3(5)) and EngineerFix's load-bearing spacing guide (16 in OC standard, especially load-bearing; 24 in OC an alternative for walls supporting only a roof and ceiling). The Spruce's drywall framing guide agrees: load-bearing studs usually 16 in apart on centre; non-load-bearing walls up to 24 in on centre.
- Height limits (same IRC table, walls supporting one floor plus a roof/ceiling, via Jaspector): 2x4 studs max 10 ft at 16 in OC and 8 ft at 24 in OC; 2x6 studs max 14 ft at 16 in OC and 12 ft at 24 in OC. Other load cases read differently from the same table — the page says so and does not present these as universal limits.
- Field count verified against a published table, not derived alone: field studs = ceil(length / spacing) + 1 — per JobsiteCalcs' stud-spacing guide (8 ft wall 7 @ 16 in OC and 5 @ 24 in OC; 10 ft wall 9 and 6; 12 ft wall 10 and 7; 16 ft wall 13 and 9; 20 ft wall 16 and 11; 24 ft wall 19 and 13; counts include one stud at each end, before corners and opening studs). The floor(length/spacing) + 1 variant undercounts any wall whose length is not an exact multiple of the spacing, so this tool uses ceil + 1 and says why.
- Actual lumber dimensions: nominal 2x4 = 1.5 x 3.5 in (38 x 89 mm), nominal 2x6 = 1.5 x 5.5 in (38 x 140 mm) — American Lumber Standard (PS 20), per this site's lumber page and EngineerFix's dimension guide (dry 2x4 after planing 1.5 x 3.5 in; 2x6 1.5 x 5.5 in) and Woodworking Network's dimension answer (same figures). Board feet billed on NOMINAL size per this site's lumber convention: BF = thickness x width x length(ft) / 12.
- Openings assembly: each opening adds 2 king studs (one per side, full height) + 2 jack/trimmer studs (one per side, carrying the header) — per OrbitalJump's framing takeoff guide (king studs 2 per opening, jack studs 2 per opening; window sill cripples typically 2-3) and NumericCore's stud guide (a king each side running full height, plus a jack each side carrying the header — four extra pieces per opening before cripples). This tool counts 2 sill cripples per window (the low end of OrbitalJump's 2-3 range, stated) and does NOT count header cripples, which vary with header height.
- Doubled jacks for wide openings: IRC header tables call for two jack studs per side once the span passes about 5 ft 6 in to 8 ft — per EngineerFix's double-jack guide (IRC requires two jack studs at each end when the span exceeds roughly 5 ft 6 in to 8 ft 0 in) and the IRC header-table rule of thumb (two jacks per side at 6 ft or more). This tool counts single jacks and flags the doubling rule; it never silently sizes headers.
- Corners allowance: 2 extra studs per corner beyond the end stud already in the field count (3-stud corner detail) — per Washington Administrative Code framing rules (not less than three studs at each corner of an exterior wall) and JobsiteCalcs (2-3 studs per corner). Partition intersections need 1-3 backing studs by the same guides and are NOT counted here — the page says so.
- Top plates: double top plate is the IRC default (R602.3.2: wood stud walls capped with a double top plate overlapping at corners and intersections; end joints offset at least 24 in) — per SBC Magazine's single-top-plate summary of R602.3.2. The single-top-plate exception from the same section needs 3 x 6 in galvanized steel ties at joints, corners and intersections AND joists/rafters centred within 1 in of the studs (same source). Stud cut length = wall height minus the plate stack (1.5 in bottom + 1.5 in per top plate); precut 92-5/8 in studs for 8 ft walls per JobsiteCalcs' precut table.
- This tool's method (stated assumptions): field studs counted over the FULL wall length, not reduced for openings — a conservative ordering assumption, since king/jack studs largely replace the field studs that would have fallen inside an opening. Waste default 10% (this site's lumber convention is 10-15%), applied to the stud count (rounded up) and to plate length. Headers counted as pieces (2-ply per opening), never sized or board-footed — header size comes from the IRC header tables (R602.7 / R502.5) and the length is the rough opening width, neither of which this tool inputs.
- Canonical example (this tool): 12 ft x 8 ft wall, 16 in OC, 2x4, 2 corners, 1 door, 1 window, double top plate, 10% waste — field 10, corners 4, kings 4, jacks 4, cripples 2, total 24, buy 27; stud length 91.5 in (7.625 ft); plates 36 ft net, 39.60 ft to buy; linear 245.48 ft; board feet 163.65 BF; cost at $4/stud + $1.20/plate-ft = $108.00 + $47.52 = $155.52. Metric twin: 4 m x 2.4 m wall, 16 in (406 mm) OC, 1 door, double top, 10% waste — field 11, total 15, buy 17; stud length 2.286 m; plates 13.20 m to buy; linear 52.06 m; board feet 113.86 BF.
Figures checked on 28 November 2026 as part of the site-wide test run (3239 automated checks, all passing). See how we calculate and test.
Safety note
What this calculator doesn't do
- This tool sizes a material order for one straight wall, not a structural design. It does not check whether your stud size, spacing and height are legal for the loads your wall actually carries — load-bearing walls, tall walls, walls under point loads and walls in high-wind or seismic areas need the IRC tables (R602.3) or an engineer. The height limits on this page (2x4: 10 ft at 16 in OC, 8 ft at 24 in OC) are the IRC table values for walls supporting one floor plus a roof/ceiling; other load cases read differently.
- Field studs are counted over the full wall length, not reduced for openings. That is a stated, conservative ordering assumption: the king and jack studs at an opening largely replace the field studs that would have fallen inside it, so the total runs slightly high. If you want the net framing count, subtract roughly one field stud per 16 in of opening width — but order from the tool's figure, not the net one, since culling crooked studs consumes the difference.
- Headers are counted as pieces only (2-ply per opening) and are never sized here. Header size depends on the opening width, the load above it and the number of storeys — use the IRC header tables (R602.7 / R502.5) or your plans, and cut each header to the rough opening width. A header guessed from this page is not a structural decision.
- Wide openings break the single-jack assumption. Once an opening span passes about 5 ft 6 in to 8 ft, the IRC header tables call for two jack studs per side instead of one (and very large or heavily loaded openings may need three). This tool counts one jack per side for every opening and flags the rule here — add the second jack per side by hand for wide openings, or the header will not have the bearing it needs.
- Corner studs are counted as 2 extra per corner (a 3-stud corner, the end stud already being in the field count). Some corner details use a different count, and a partition wall meeting this wall needs 1-3 backing studs of its own that this tool does not count — add those by hand if your wall has an intersecting partition.
- Window cripples are counted as 2 per window, below the sill only. Cripples above the header (on load-bearing walls, where the header does not reach the top plate) vary with the header height and are not counted — cut them from stud offcuts on site, which is why the waste allowance matters. Door openings have no cripples.
- The waste allowance (default 10%) covers culling crooked, bowed or split studs and cutting losses. Framing lumber arrives imperfect and a crooked stud in a wall that will be drywalled shows for the life of the building — do not order at 0% waste unless every stud is already on site and straight.
- Plate lengths are given as continuous feet, not as purchasable board lengths. Lumberyards sell plates in fixed lengths (commonly 8, 10, 12, 14 and 16 ft): buy lengths that cover each run with joints offset at least 24 in in a double top plate, and the waste allowance covers the offcuts from those joints.
- Cost is an estimate only, from the prices you enter — no prices are preset. Stud and plate prices swing with species, grade, length and region; always get a yard quote before budgeting, and compare the total lumber figure (board feet plus linear feet) rather than the stud count alone.
- This page does not cover sheathing, drywall, insulation, bracing, hold-downs, anchor bolts or fire blocking. For the sheets that go on the frame, use the drywall calculator; for board feet on any other lumber, the lumber calculator.
Framing Calculator — frequently asked questions
How many studs do I need for a 10 ft wall?
A 10 ft wall needs 9 field studs at 16 in OC (ceil(120 / 16) + 1 = 8 + 1) or 6 field studs at 24 in OC (ceil(120 / 24) + 1 = 5 + 1) — before corners and openings. Add 2 studs per corner, 4 per opening (2 king + 2 jack) and 2 sill cripples per window, then waste: a 10 ft wall at 16 in OC with 2 corners and 1 door is 9 + 4 + 4 = 17 studs before waste, 19 at 10% waste.
How many studs do I need for a 12 ft wall?
A 12 ft wall needs 10 field studs at 16 in OC (ceil(144 / 16) + 1) or 7 at 24 in OC (ceil(144 / 24) + 1). With 2 corners, 1 door and 1 window at 16 in OC the full count is 10 field + 4 corner + 4 king + 4 jack + 2 cripples = 24 studs before waste, 27 to buy at 10% waste — plus 39.60 ft of plate (36 ft net, double top plate) and 163.65 board feet in total.
How many board feet of lumber do I need to frame a wall?
Board feet are billed on nominal size: BF = thickness x width x length in feet / 12. A 12 ft x 8 ft wall at 16 in OC, 2x4, 2 corners, 1 door, 1 window, double top plate, 10% waste needs 27 studs at 7.625 ft = 137.25 BF of studs plus 39.60 ft of plate at 0.67 BF/ft = 26.40 BF, for 163.65 BF total and 245.48 linear ft. The same wall in 2x6 needs 10 studs at 7.625 ft = 76.25 BF of studs plus 36 ft of plate at 1.00 BF/ft = 36 BF, for 112.25 BF before waste — fewer studs are not the same as less lumber when the studs are wider.
How many studs do I need for a wall measured in metres?
Convert the length to inches first (metres x 39.3701), then field studs = ceil(length in inches / spacing in inches) + 1. A 4 m wall is 157.48 in, so at 16 in (406 mm) OC it needs ceil(157.48 / 16) + 1 = 11 field studs; at 24 in (610 mm) OC it needs ceil(157.48 / 24) + 1 = 8 field studs. Add 2 per corner, 4 per opening and 2 sill cripples per window, then waste, exactly as in feet — the tool does the conversion if you enter metres above.
How many studs do I need for a 4 m wall?
A 4 m long x 2.4 m high wall at 16 in (406 mm) OC with 1 door, no corners and no windows needs 11 field studs + 2 kings + 2 jacks = 15 studs before waste, 17 to buy at 10% waste. Stud length is 2.4 m minus the 4.5 in (114 mm) plate stack = 2.286 m each. Plates are 4 m x 3 runs (1 bottom + 2 top) = 12 m net, 13.20 m to buy. Total lumber is 52.06 m (170.79 ft) and 113.86 board feet. At 24 in (610 mm) OC the same wall needs 8 field studs, 12 total, 14 to buy — only where 24 in OC is permitted.
How much does it cost to frame a wall?
This calculator presets no prices — enter your price per stud and price per plate-foot for a lumber total. As an illustration with entered prices, the 12 ft x 8 ft wall above (27 studs to buy, 39.60 ft of plate to buy) at $4 per stud and $1.20 per plate-foot costs 27 x $4 = $108.00 + 39.60 x $1.20 = $47.52 = $155.52 for studs and plates. Headers, sheathing, drywall, insulation, nails and labour are not in that figure — price those separately.
When should I use 16 inch vs 24 inch stud spacing?
Use 16 in OC for load-bearing walls — it is the IRC standard, it gives the full height allowance (2x4 up to 10 ft, 2x6 up to 14 ft), and it keeps drywall flat with standard 1/2 in sheets. Use 24 in OC only for non-load-bearing interior partitions, walls carrying just a roof/ceiling, or advanced framing with 2x6 studs, where it saves lumber (3 studs on a 12 ft wall) and leaves wider insulation cavities — and note the height limits tighten (2x4 only to 8 ft at 24 in OC) and drywall may need 5/8 in sheets to avoid flex.
How many king studs and jack studs do I need per opening?
Two king studs and two jack studs per opening: one king and one jack on each side. The king runs full height from bottom plate to top plate and anchors the assembly; the jack (trimmer) sits beside it, cut to the header height, and carries the header load down to the bottom plate. Wide openings (roughly over 5 ft 6 in to 8 ft of span) need two jacks per side under the IRC header tables — add those by hand, since this tool counts one jack per side.
How many extra studs do I need for corners?
Two extra studs per corner, beyond the end stud already counted in the field layout — that makes a 3-stud corner, the standard exterior-wall detail. A wall with 2 corners therefore adds 4 studs. Count each corner once across the whole room: if you run the tool per wall, assign each corner to one wall only, or the room total will be 8 studs high. A partition meeting this wall needs 1-3 backing studs of its own, which this tool does not count.
Do I need a single or double top plate?
Double, in nearly every case: it is the IRC default (R602.3.2), it overlaps at corners and intersections to tie the walls together, and its joints are offset at least 24 in. A single top plate is a code exception, allowed only with 3 x 6 in galvanized steel ties at every joint, corner and intersection, nailed with six 8d nails per side, and with joists or rafters centred within 1 in of the studs below. If either condition is not met, frame the double top plate.
How long should wall studs be cut?
Wall height minus the plate stack: 1.5 in for the bottom plate plus 1.5 in per top plate. An 8 ft (96 in) wall with a double top plate takes 96 - 4.5 = 91.5 in studs; with a single top plate, 96 - 3 = 93 in studs. The store-bought precut equivalent for an 8 ft double-top wall is 92-5/8 in, which is fitted on site. Never order full-height studs for the wall height — they will not fit between the plates.
What is the actual size of a 2x4 and a 2x6 stud?
A nominal 2x4 is actually 1.5 x 3.5 in (38 x 89 mm) and a nominal 2x6 is actually 1.5 x 5.5 in (38 x 140 mm), after drying and planing under the American Lumber Standard (PS 20). Lengths are true: an 8 ft stud is 8 ft long before cutting. Board feet, however, are billed on the nominal size, so a 2x4 stud 7.625 ft long is 2 x 4 x 7.625 / 12 = 5.08 board feet.
Next step
Take the stud breakdown (field, corner, king, jack and cripple counts separately) and the buy plate length to the lumberyard — and confirm the stud size, spacing and top-plate choice against your plans or the IRC tables before ordering, since a load-bearing wall framed at 24 in OC is a code failure, not a saving. Then price the sheets with the drywall calculator and the insulation with the insulation calculator before the frame goes up.