Roof Snow Load Calculator

A roof snow load is a ground snow load put through four adjustments: how exposed the roof is to wind (Ce), how much heat escapes through it (Ct), how important the building is (Is), and how steep the roof is (Cs). This roof snow load calculator runs the ASCE 7-16 Chapter 7 method — the standard the US building codes reference — in pounds per square foot and kilopascals. Enter your ground snow load pg from the ASCE 7 Hazard Tool or your local building department (there is no default: pg is site-specific and must never be guessed), pick your terrain and exposure, thermal condition and risk category, then the roof slope and surface. The result is the flat-roof snow load pf with its minimum-load check, the slope factor Cs, the sloped-roof design load ps, the rain-on-snow surcharge where it applies, the balanced snow depth, and — if you enter a roof area — the total load on the whole roof in pounds, tons and kilonewtons. A second mode on the same page works the other way round: enter the depth of the snow already on the roof and its type, and the tool turns depth into weight — pounds per square foot, the total weight on the roof, and the share of your roof's design load. These are preliminary planning figures, not a structural design: drift, unbalanced snow, sliding snow and ponding are out of scope for this tool, and the final design load must come from a licensed professional engineer. For the shingles and squares the load sits on, use the roofing calculator; and for the pitch the slope factor comes from, the roof pitch calculator.

Quick answer: For a ground snow load pg of 30 psf, Terrain C, partially exposed (Ce = 1.0), heated building (Ct = 1.0), Risk Category II (Is = 1.0): pf = 0.7 x 1.0 x 1.0 x 1.0 x 30 = 21.0 psf (1.01 kPa) — above the 20 psf minimum, so 21.0 psf governs. On a 6:12 pitch (26.6 degrees), warm shingle roof, Cs = 1.0, so the sloped load ps = 21.0 psf (1.01 kPa). The balanced snow depth is 21.0 / 17.9 = 1.17 ft (14.1 in, 0.36 m) at a snow density of 17.9 pcf.
Design-load mode sizes a roof from its ground snow load pg. Depth-to-weight mode weighs the snow already on the roof from its measured depth and type. Only the fields for your mode are used — the other mode's fields are ignored.
From the ASCE 7 Hazard Tool (asce7hazardtool.online) or your local building department — the mapped 50-year ground snow load for your exact site. NO default: pg is site-specific and must never be guessed. Typical US values run 5–120 psf (0.24–5.75 kPa); 0 means no design snow load.
The ground roughness around the site, from ASCE 7 Table 7.3-1. Terrain B is built-up or wooded; C is open country with scattered obstructions; D is flat, unobstructed ground such as shoreline or open plains. Most suburban sites are B or C.
How much wind reaches the roof to scour snow off it. Sheltered roofs keep their snow (higher Ce, higher load); fully exposed roofs lose snow to the wind (lower Ce). Combined with terrain this sets Ce: for example Terrain C partially exposed is Ce = 1.0.
From ASCE 7 Table 7.3-2. Heat escaping through the roof melts snow from below, so heated buildings take Ct = 1.0 and unheated ones 1.2 — an unheated shed carries 20% more design snow load than the same roof on a heated house.
From ASCE 7 Table 1.5-2. The importance factor raises the design load for buildings where failure would endanger many people or essential services. A normal house is Category II (Is = 1.0).
0 degrees is flat. Enter degrees, or pick "rise in 12" and enter the rise (6 for a 6:12 roof). Common pitches: 4:12 = 18.4 degrees, 6:12 = 26.6 degrees, 8:12 = 33.7 degrees, 12:12 = 45 degrees.
Whether snow slides off the surface. Metal and smooth membrane roofs shed snow at lower slopes than shingles, so a slippery surface gets a smaller Cs on a steep roof. Snow guards or obstructions that stop sliding mean no slope reduction — pick non-slippery if guards are fitted.
For a total roof load. Leave blank for the per-square-foot load only. Use the sloped roof area, not the footprint — the roofing calculator gives squares and bundles from the same area.
How deep the snow is on the roof, measured from the roof surface to the top of the snow — from the ground with a roof rake or a long pole, never by climbing onto a loaded roof. Depth mode only.
Planning rates from FEMA P-957 and Maine EMA (see the snow-weight table below). When you are not sure, use wet and heavy — old snow that has thawed and refrozen can be nearly as heavy. Depth mode only.
The horizontal projection of the roof — the footprint, overhangs included — not the sloped surface: snow falls straight down. Leave blank for the per-square-foot load only. Depth mode only.
The design snow load your roof was built for, from the original plans or your building department — the tool shows the snow's load as a percentage of it, and the depth that would reach it. Leave blank to compare against the 20 psf typical-roof rule of thumb instead. Depth mode only.

Planning this project? Save to Pinterest to find this calculator again later.

How to use the Roof Snow Load Calculator

  1. Pick the mode first: design-load mode for a roof you are sizing from its ground snow load pg, depth-to-weight mode for snow already on the roof. Only the fields for your mode are used — the other mode's fields are ignored, so you do not need to clear them.
  2. Look up your ground snow load pg FIRST, before touching the tool: the ASCE 7 Hazard Tool (asce7hazardtool.online) by address, or your local building department's adopted map. Write the number down in psf (or kPa) — the tool has no default and no location database, because pg is site-specific and a guessed pg is a wrong answer.
  3. Pick the terrain category (B urban/suburban, C open terrain, D flat unobstructed) and the roof exposure (sheltered, partially exposed, fully exposed). Together they set Ce from ASCE 7 Table 7.3-1 — for example Terrain C partially exposed is Ce = 1.0, Terrain B sheltered is 1.2, Terrain D fully exposed is 0.8.
  4. Pick the thermal factor Ct: 1.0 for a heated building (most houses), 1.1 for a structure kept just above freezing, 1.2 for an unheated or open-air structure, 1.3 for a freezer building, 0.85 for a continuously heated greenhouse. Then the risk category Is: 0.80 for Category I (farm/storage), 1.00 for Category II (standard homes), 1.10 for Category III (schools/assembly), 1.20 for Category IV (hospitals/emergency).
  5. Enter the roof slope in degrees (0 is flat), or pick "rise in 12" and enter the rise — 6 for a 6:12 roof, which is 26.6 degrees. Then the surface: non-slippery for asphalt shingles, wood or rough membrane; slippery for standing-seam metal or smooth membrane with nothing to stop the snow sliding. If snow guards are fitted, pick non-slippery.
  6. Read the flat-roof load pf first, with its minimum-load check: the tool shows the formula value (0.7 x Ce x Ct x Is x pg) and the minimum (Is x pg when pg is 20 psf or less, Is x 20 psf when pg is over 20 psf), and the larger of the two governs. A sheltered roof in a light-snow area is the case where the minimum usually governs.
  7. Read the slope factor Cs and the sloped-roof design load ps = Cs x pf. On a low-slope roof Cs is 1.0 and ps equals pf; on a steep roof Cs falls — a 45-degree slippery metal roof keeps only 45% of the flat load, while the same pitch in shingles keeps 63%.
  8. Check the rain-on-snow line: where pg is 20 psf or less and the roof is low-slope (5 degrees or less here), the tool adds 5 psf to the design load per ASCE 7-16 §7.10. The line is shown separately so you can see exactly when it applied.
  9. Read the balanced snow depth (pf divided by the snow density) as a planning depth — about 14 inches for the 21 psf example — and, if you entered a roof area, the total load on the whole roof in pounds, US tons and kilonewtons. Take the psf/kPa design load, not the total, to your engineer: the total is a sense-check, the per-square-foot load is the design number.
  10. Depth-to-weight mode: measure the snow depth on the roof from the ground — a roof rake or a long pole, never by climbing onto a loaded roof — and pick the snow type honestly. Fresh light snow is 3 psf per foot, average new snow about 5, wet heavy snow 21, old packed snow about 10, and ice about 57. When in doubt, use wet and heavy: old snow that has thawed and refrozen can be nearly as heavy as fresh wet snow.
  11. Read the load in psf and kPa, the depth that would reach the 20 psf typical-roof figure, and — if you entered your roof's design load — the share of that design load and the depth that would reach it. Enter the roof footprint (horizontal projection, overhangs included) for the total weight in pounds, tons and kilonewtons. A load over 100% of the design load is not a calculation to sit on — call a professional and keep people out from under the roof.

Roof Snow Load Calculator formula

Ground snow load pg is your input, in psf or kPa (1 psf = 0.0478803 kPa; 1 kPa = 20.8854 psf). Exposure factor Ce from ASCE 7 Table 7.3-1 by terrain and exposure: Terrain B — fully exposed 0.9, partially exposed 1.0, sheltered 1.2; Terrain C — 0.9, 1.0, 1.1; Terrain D — 0.8, 0.9, 1.0. Thermal factor Ct from Table 7.3-2: heated 1.0, just above freezing 1.1, unheated/open 1.2, freezer 1.3, continuously heated greenhouse 0.85. Importance factor Is from Table 1.5-2: Category I 0.80, II 1.00, III 1.10, IV 1.20. Flat-roof snow load (ASCE 7-16 Eq. 7.3-1): pf = 0.7 x Ce x Ct x Is x pg. Minimum flat-roof load (§7.3.4): pf >= Is x pg when pg <= 20 psf; pf >= Is x 20 psf when pg > 20 psf — the larger of the formula value and the minimum governs. Slope factor Cs from Fig. 7.4-1 (piecewise-linear readings of the standard's curves): warm roof (Ct <= 1.0), slippery surface — Cs = 1.0 for slope <= 15 degrees, Cs = 1 - (slope - 15) / 55 for 15 < slope <= 70 degrees, 0 above 70 degrees; warm roof, non-slippery surface — Cs = 1.0 for slope <= 30 degrees, Cs = 1 - (slope - 30) / 40 for 30 < slope <= 70 degrees, 0 above 70 degrees; cold roof (Ct > 1.0) — Cs = 1.0 for slope <= 30 degrees, Cs = 1 - (slope - 30) / 40 for 30 < slope <= 70 degrees, 0 above 70 degrees. Sloped-roof snow load (Eq. 7.4-1): ps = Cs x pf. Rain-on-snow surcharge (§7.10): +5 psf where pg <= 20 psf on a low-slope roof (5 degrees or less in this tool — see the limitations for the W/50 test). Design load = ps + rain-on-snow surcharge where it applies. Snow density (Eq. 7.7-1): gamma = 0.13 x pg + 14 pcf, capped at 30 pcf (1 pcf = 16.0185 kg/m3). Balanced snow depth: hb = pf / gamma (feet; x 12 for inches, x 0.3048 for metres). Total roof load (when an area is entered): ps x roof area — pounds (psf x ft2), US tons = pounds / 2,000, kilonewtons = kPa x m2. Example (a): pg 30 psf, Terrain C, partially exposed (Ce = 1.0), heated (Ct = 1.0), Category II (Is = 1.0) — pf = 0.7 x 1.0 x 1.0 x 1.0 x 30 = 21.0 psf (1.01 kPa); minimum = 1.0 x 20 = 20 psf, so 21.0 psf governs. Slope 26.6 degrees (6:12), warm shingle roof — Cs = 1.0 (slope <= 30 degrees), ps = 21.0 psf (1.01 kPa). Density gamma = 0.13 x 30 + 14 = 17.9 pcf (286.7 kg/m3); depth hb = 21.0 / 17.9 = 1.17 ft (14.1 in, 0.36 m). With a 2,000 sq ft roof area: total = 21.0 x 2,000 = 42,000 lb = 21.0 US tons (19.05 tonnes, 186.8 kN). Example (b): pg 40 psf, Ce 0.9, Ct 1.0, Is 1.0, slope 45 degrees, slippery metal roof — pf = 0.7 x 0.9 x 1.0 x 1.0 x 40 = 25.2 psf (1.21 kPa); Cs = 1 - (45 - 15) / 55 = 0.45; ps = 0.45 x 25.2 = 11.45 psf (0.55 kPa). Example (c): pg 15 psf, Ce 1.0, Ct 1.0, Is 1.0, slope 3 degrees — pf formula = 0.7 x 15 = 10.5 psf; minimum = 1.0 x 15 = 15.0 psf, so pf = 15.0 psf (0.72 kPa) governs; rain-on-snow applies (pg <= 20, low slope): design load = 15.0 + 5 = 20.0 psf (0.96 kPa). Depth to weight (FEMA P-957 / Maine EMA planning rates): load (psf) = snow depth (ft) x rate, where the rate is 3 psf per foot for fresh light and dry snow, about 5 psf per foot for average new snow (10-12 in ≈ 5 psf), 21 psf per foot for fresh wet and heavy snow, about 10 psf per foot for old packed snow (3-5 in ≈ 5 psf, up to about 20 psf per foot when wet and dense), and about 57 psf per foot for ice (a little under 5 psf per inch). The rate in psf per foot is also the snow density in pcf (1 pcf = 16.0185 kg/m3). Total weight = load x roof footprint area — pounds (psf x ft2), US tons = pounds / 2,000, kilonewtons = kPa x m2. Share of design load = load / design load x 100; the depth that reaches the design load = design load / rate. Example (d): 2 ft of old packed snow — load = 2 x 10 = 20 psf (0.96 kPa), exactly the typical-roof figure, reached at 2 ft; on a 2,000 sq ft footprint that is 20 x 2,000 = 40,000 lb = 20.0 US tons (18.14 tonnes, 177.9 kN). The same 2 ft as wet heavy snow would be 42 psf (2.01 kPa) — 210% of a 20 psf design load.

Worked example

Standard house, moderate snow country: pg = 30 psf, Terrain C, partially exposed (Ce = 1.0), heated house (Ct = 1.0), Risk Category II (Is = 1.0), 6:12 pitch (26.6 degrees), asphalt shingles. Step one — flat load: pf = 0.7 x 1.0 x 1.0 x 1.0 x 30 = 21.0 psf (1.01 kPa). Step two — minimum check: pg is over 20 psf, so the minimum is Is x 20 = 20 psf; 21.0 beats 20, so 21.0 psf governs. Step three — slope factor: warm roof (Ct = 1.0), non-slippery shingles, slope 26.6 degrees is under 30 degrees, so Cs = 1.00. Step four — sloped load: ps = 1.00 x 21.0 = 21.0 psf (1.01 kPa). Step five — rain-on-snow: pg is over 20 psf, so no surcharge. Step six — depth: density gamma = 0.13 x 30 + 14 = 17.9 pcf (286.7 kg/m3); balanced depth hb = 21.0 / 17.9 = 1.17 ft (14.1 in, 0.36 m). Step seven — total: with a 2,000 sq ft roof, 21.0 x 2,000 = 42,000 lb = 21.0 US tons (19.05 tonnes, 186.8 kN).

Steep metal roof, heavier snow: pg = 40 psf, Ce = 0.9 (fully exposed), Ct = 1.0, Is = 1.0, slope 45 degrees, slippery standing-seam metal. Step one — flat load: pf = 0.7 x 0.9 x 1.0 x 1.0 x 40 = 25.2 psf (1.21 kPa); minimum 20 psf does not govern. Step two — slope factor: warm slippery roof at 45 degrees, Cs = 1 - (45 - 15) / 55 = 0.45. Step three — sloped load: ps = 0.45 x 25.2 = 11.45 psf (0.55 kPa) — less than half the flat load, because the steep metal roof sheds snow. The same 45-degree pitch in shingles would keep Cs = 1 - (45 - 30) / 40 = 0.63, ps = 15.75 psf: the surface matters as much as the pitch.

Light snow, low slope, minimum governs: pg = 15 psf, Ce = 1.0, Ct = 1.0, Is = 1.0, slope 3 degrees. Step one — flat load: pf = 0.7 x 15 = 10.5 psf. Step two — minimum: pg is 20 psf or less, so the minimum is Is x pg = 15.0 psf (0.72 kPa) — the minimum governs, not the formula value. Step three — rain-on-snow: pg is 20 or less and the slope is low, so add 5 psf: design load = 15.0 + 5 = 20.0 psf (0.96 kPa). This is the case that catches people out: a favourable exposure factor that cuts the formula load to 10.5 psf still leaves a 20 psf design load once the minimum and the rain surcharge are applied.

Metric version: pg = 1.44 kPa (about 30 psf), Terrain C, partially exposed, heated, Category II, slope 26.6 degrees, shingles. Convert first: 1.44 / 0.0478803 = 30.07 psf. Then pf = 0.7 x 30.07 = 21.05 psf (1.01 kPa); minimum 20 psf (0.96 kPa) does not govern; Cs = 1.0; ps = 21.05 psf (1.01 kPa). Depth: gamma = 0.13 x 30.07 + 14 = 17.9 pcf; hb = 21.05 / 17.9 = 1.18 ft = 0.36 m. With a 185.81 m2 roof (2,000 sq ft): total = 1.01 kPa x 185.81 m2 = 187.3 kN.

Depth to weight: 2 ft of old packed snow on a 2,000 sq ft roof footprint, design load 20 psf. Step one — rate: old packed snow plans at 10 psf per foot (FEMA/Maine EMA range 10–20, denser when wet). Step two — load: 2 x 10 = 20.0 psf (0.96 kPa). Step three — total: 20.0 x 2,000 = 40,000 lb = 20.0 US tons (18.14 tonnes, 177.9 kN). Step four — share of design load: 20.0 / 20 = 100% — the snow is exactly at the design load, and any more snow, or rain on top of it, takes the roof past it. The same 2 ft as wet heavy snow would be 2 x 21 = 42 psf (2.01 kPa), 210% of the design load, and the design load would be reached at 20 / 21 = 0.95 ft (11.4 in, 0.29 m) of wet snow.

Exposure factor Ce — ASCE 7 Table 7.3-1:

TerrainFully exposedPartially exposedSheltered
Terrain B (urban / suburban)0.91.01.2
Terrain C (open terrain)0.91.01.1
Terrain D (flat, unobstructed)0.80.91.0
Sheltered means obstructions at least as tall as the roof within 10 roof-heights upwind; fully exposed means no obstructions within that distance. Most suburban houses are Terrain B or C, partially exposed — Ce = 1.0, the value in the worked examples above.

Slope factor Cs — ASCE 7-16 Figure 7.4-1 (piecewise-linear readings):
Roof slopeWarm roof, slippery (metal / membrane)Warm roof, non-slippery (shingles)Cold roof (Ct > 1.0)
15 degrees (about 3:12)1.001.001.00
30 degrees (about 7:12)0.731.001.00
45 degrees (12:12)0.450.630.63
60 degrees0.180.250.25
70 degrees and over0.000.000.00
The table reads the standard's curves as straight lines between the anchor slopes (15 and 70 degrees for warm slippery; 30 and 70 degrees for the other two), accurate to about 0.02 in Cs. Above 70 degrees the standard assumes no design snow load — but a roof that steep still needs its dead load and wind checked, and snow sliding off it lands on whatever is below.

How much snow can a roof hold — snow weight by type (FEMA P-957; Maine EMA citing IBHS):
Snow or ice on the roofWeightDepth that reaches 20 psf (0.96 kPa)
Fresh snow, light and dryAbout 3 lb/ft² per foot of depthAbout 6–7 ft (2.0 m)
New snow, averageAbout 5 lb/ft² per 10–12 inAbout 4 ft (1.22 m)
Fresh snow, wet and heavyAbout 21 lb/ft² per foot of depthAbout 1 ft (0.30 m)
Old, packed snowAbout 5 lb/ft² per 3–5 inAbout 2 ft (0.61 m)
IceA little under 5 lb/ft² per inch; about 57 lb/ft² per footAbout 4 in (10 cm)
The 20 psf figure is the typical-roof rule of thumb from Maine EMA (citing IBHS), not a rating for any specific roof — roofs in snowy areas are designed for more, and an older or deteriorated roof may hold less. Depth alone never fixes the load: 2 ft of old snow plus 2 ft of new snow can reach about 60 psf (Maine EMA, citing IBHS). For the design load your roof was actually built for, use the tool above with your site's ground snow load pg.

Measurement tips

  • Get pg from the ASCE 7 Hazard Tool or your building department, never from memory. pg is the one input that can be wrong by a factor of two without the answer looking wrong: 30 psf and 60 psf both produce plausible-looking psf figures, and only the map tells you which one your site actually has. Print or save the hazard-tool result with the address on it.
  • Check which code edition your jurisdiction adopted before you trust any Cs figure. This tool implements ASCE 7-16 with the importance factor Is exposed, because most US jurisdictions still reference it — but ASCE 7-22 folds Is into the updated ground-snow hazard maps and writes pf = 0.7 x Ce x Ct x pg, and its Figure 7.4-1 curves differ slightly from the 7-16 readings here. If your building department adopted 7-22, take this page's numbers as a cross-check and have your engineer run the 7-22 edition.
  • Run the minimum-load check in your head before you trust the formula value: if pg is 20 psf or less, the design load can never be below Is x pg; if pg is over 20, never below Is x 20. A sheltered site with a low Ce is exactly where the minimum takes over — the worked light-snow example (10.5 psf formula, 15 psf minimum, 20 psf with rain) is the pattern to watch for.
  • Measure the slope from the roof you have, not the pitch you think it is. A 6:12 roof is 26.6 degrees, a 4:12 is 18.4 degrees, an 8:12 is 33.7 degrees — and the Cs threshold for shingles sits at 30 degrees, right between a 6:12 and an 8:12. Measuring a 6:12 as an 8:12 by eye cuts Cs from 1.00 to 0.91 on a warm shingle roof and understates the load by 9%.
  • Pick the surface honestly: a standing-seam metal roof with snow guards is a non-slippery roof for this calculation, because the guards stop the sliding the slippery curve assumes. The same applies to a membrane roof with parapets or equipment that traps the snow. The slippery reduction is only for unobstructed surfaces with clear space below the eaves for the snow to land.
  • Remember the load acts on the horizontal projection, not on the sloped surface. ps is pounds per square foot of horizontal roof area — the same square footage the roofing calculator reports as squares. Do not multiply ps by the sloped surface area: that double-counts the pitch and overstates the total load.
  • Use the total-load figure as a sense-check, not a design number. 42,000 lb on a 2,000 sq ft roof sounds enormous until you divide it back down: it is 21 psf, about the weight of a 14-inch layer of snow. If the total looks impossible, check the area first — a footprint entered as roof area on a steep roof understates the area and the total together.
  • Convert units through psf, not through memory: 1 psf = 0.04788 kPa, so 21 psf is 1.01 kPa and 1 kPa is 20.89 psf. A ground snow load quoted as 1.5 kPa is 31.3 psf, not 15 psf — the most common metric mistake on this page is reading kPa as if it were psf, which understates the load twenty-fold.
  • In snow country, check the roof structure for tile and slate the same way you check it for snow: both are weight the framing must carry, and a tile roof plus a 21 psf snow load is a different structure from a shingle roof with the same snow. The roof replacement cost guide notes the same check for heavy materials.
  • If the roof already has snow on it, do not climb it to measure anything. Snow load is estimated from the ground, from plans, or from the hazard tool — never from standing on a loaded roof. A roof that is visibly sagging, creaking, or shedding interior cracks under snow is a call-a-professional-now situation, not a calculation.
  • Measure snow depth from the ground, with a roof rake or a long pole marked in inches — never by climbing onto a loaded roof. Measure in several places: wind scours the windward side and drifts the leeward side, so one reading can be half or double the average. If the readings disagree, use the deepest one for the load check, and the wet, heavy rate if the snow has thawed and refrozen.

Common mistakes

  • Guessing pg. The tool has no default for a reason: pg runs from 0 psf in southern Florida to 100+ psf in mountain areas, and a pg guessed from the nearest town you remember can be off by 30–50 psf. The ASCE 7 Hazard Tool takes an address and a minute; a guessed pg takes the whole answer with it.
  • Forgetting the minimum load. The formula 0.7 x Ce x Ct x Is x pg is only half of §7.3: the minimum (Is x pg, or Is x 20 psf above 20 pg) governs whenever the factors are favourable. On a sheltered site the formula can read 10.5 psf while the design load is 15 psf — and 20 psf once rain-on-snow is added.
  • Applying the rain-on-snow surcharge to a steep roof, or forgetting it on a flat one. The +5 psf applies where pg is 20 psf or less on a low-slope roof only. Adding it to a 45-degree roof overstates the load; leaving it off a flat roof in a 15 psf zone understates the design load by a quarter.
  • Using the 7-22 formula with a 7-16 pg, or the other way round. ASCE 7-22 folds the importance factor into the hazard maps, so its pf = 0.7 x Ce x Ct x pg has no Is term; ASCE 7-16 keeps Is exposed. Mixing the two — a 7-22 pg with an Is multiplier, or a 7-16 pg without one — double-counts or drops the importance factor by up to 20%.
  • Reading Cs off the wrong curve. A warm shingle roof keeps Cs = 1.0 to 30 degrees; a warm metal roof starts shedding at 15 degrees; a cold roof keeps full load to 30 degrees. Picking the metal curve for a shingle roof at 45 degrees gives Cs = 0.45 instead of 0.63 and understates the load by nearly a third.
  • Treating the balanced load as the whole design. Drift at parapets and roof steps, unbalanced snow on a gable (0.3 x ps windward, ps plus drift leeward), and sliding snow from an upper roof can all exceed the balanced load this tool reports. The balanced figure is the starting point of the design, not the design.
  • Multiplying ps by the sloped surface area. ps is defined on the horizontal projection of the roof. A 2,000 sq ft footprint under a 6:12 roof is 2,236 sq ft of sloped surface — multiplying 21 psf by 2,236 sq ft gives 46,956 lb, about 12% over the correct 42,000 lb. Use the footprint (or the roofing calculator's squares) for the total, never the sloped area.
  • Assuming a steep roof carries no snow. Cs reaches 0 only above 70 degrees. A 45-degree shingle roof still carries 63% of the flat load, and a 60-degree roof still carries 25%. Snow also slides off a steep roof onto whatever is below — a lower roof, a walkway, a porch — which then carries a sliding-snow surcharge this tool does not calculate.
  • Using a summer pg or a 50-year-old map. Ground snow loads are mapped values with a 50-year mean recurrence interval, and jurisdictions update their adopted maps when the standard is revised. A pg from an old code book, a neighbouring county, or a weather website's "average snowfall" (inches of snow, not pounds per square foot) is not the mapped pg.
  • Sizing structure from this page. The limitations say it plainly and it bears repeating: this is a preliminary planning estimate. Rafter sizes, truss designs, beam spans and connection details come from a licensed PE/SE with the adopted code edition, the site-specific pg, and the drift and unbalanced checks this tool does not do.

Factors that affect accuracy

  • Ground snow load pg: every extra 10 psf of pg adds 7.0 psf to pf at Ce = Ct = Is = 1.0 (0.7 x 10), before the minimum check. pg is the dominant input by far — a site at 50 psf carries more than double the design load of a site at 20 psf with identical factors.
  • Exposure Ce: sheltered (1.2) vs fully exposed (0.9) in the same terrain moves pf by a third — at pg 30, Ct = Is = 1.0, pf is 25.2 psf sheltered in Terrain B against 18.9 psf fully exposed. Wind scouring is a real load reduction, but only where the wind actually reaches the roof.
  • Thermal factor Ct: an unheated structure (Ct = 1.2) carries 20% more design snow load than the same roof heated (Ct = 1.0) — at pg 30, pf is 25.2 psf unheated against 21.0 psf heated. A cold ventilated roof (Ct = 1.1) sits in between at 23.1 psf.
  • Importance factor Is: Category IV (1.20) carries 50% more than Category I (0.80) on the same site — at pg 30, pf is 25.2 psf for a hospital against 16.8 psf for a farm building, before the minimum check (which also scales with Is).
  • Roof slope: on a warm shingle roof Cs stays 1.0 to 30 degrees, then falls linearly — 0.75 at 40 degrees, 0.50 at 50, 0.25 at 60, 0 at 70. A 45-degree shingle roof carries 63% of the flat load; the same pitch in slippery metal carries 45%.
  • Surface slipperiness: at 45 degrees, slippery metal (Cs = 0.45) carries about 29% less than shingles (Cs = 0.63) on the same warm roof — 11.45 psf against 15.75 psf at pf = 25.2 psf. Below 15 degrees the surface makes no difference at all (Cs = 1.0 for both).
  • Minimum load: the minimum binds hardest where the factors are favourable — low Ce, low pg. At pg 10, Ce 0.9, the formula gives 6.3 psf but the minimum (Is x pg = 10 psf) governs; at pg 30, Ce 0.8, the formula gives 16.8 psf but the 20 psf minimum governs. The minimum is a floor, not a rounding.
  • Rain-on-snow: +5 psf where pg is 20 psf or less on a low-slope roof. On a 15 psf design load that is a 33% increase; on a 10 psf minimum-governed load it is a 50% increase. In light-snow country the surcharge is often the largest single addition to the design load.
  • Snow density: gamma = 0.13 x pg + 14 pcf, capped at 30 pcf — so at pg 10 the density is 15.3 pcf and a foot of snow weighs 15.3 psf, while at pg 50 it is 20.5 pcf and a foot weighs 20.5 psf. Heavier snow country has denser snow, so depth alone understates the load difference between regions.
  • Roof area: the total load scales linearly with area — 21 psf is 21,000 lb on 1,000 sq ft and 42,000 lb on 2,000 sq ft. The per-square-foot load is the design number; the total only tells you how much structure the whole roof represents, and it is the number to compare against a roof's rated capacity when one is published.
  • Snow type (depth-to-weight mode): the rate per foot of depth runs 3 psf (fresh light snow) to 57 psf (ice) — a nineteen-fold range. At 2 ft of depth that is 6 psf light and dry against 42 psf wet and heavy, so the type you pick moves the answer far more than an inch of depth either way. Old packed snow sits in the middle at about 10 psf per foot planned, up to about 20 when wet and dense.

Sources & assumptions

  • Flat-roof load pf = 0.7 x Ce x Ct x Is x pg (ASCE 7-16 Eq. 7.3-1) and sloped-roof load ps = Cs x pf (Eq. 7.4-1). This page implements the ASCE 7-16 form with the importance factor Is exposed — ASCE 7-22 folds Is into the updated ground-snow hazard maps and writes pf = 0.7 x Ce x Ct x pg, so do not mix the editions; the edition is labelled on the page.
  • Minimum flat-roof load (ASCE 7-16 §7.3.4): pf >= Is x pg when pg <= 20 psf; pf >= Is x 20 psf when pg > 20 psf. Verified against the worked example on steelcalculator.app's ASCE 7 snow load reference (pg 30, Ce 1.0, Ct 1.0, Is 1.0 -> pf = 21.0 psf, minimum 20 psf, 21 psf governs) and the StructEd ASCE 7-16 balanced snow load guide.
  • Exposure factor Ce from ASCE 7 Table 7.3-1, as tabulated on the same steelcalculator.app reference: Terrain B — fully exposed 0.9, partially exposed 1.0, sheltered 1.2; Terrain C — 0.9, 1.0, 1.1; Terrain D — 0.8, 0.9, 1.0. Windswept mountain sites (Ce down to 0.7) and Alaska rows are not offered here — see the limitations.
  • Thermal factor Ct from ASCE 7 Table 7.3-2 (heated 1.0; kept just above freezing 1.1; unheated/open 1.2; freezer 1.3; continuously heated greenhouse 0.85) and importance factor Is from Table 1.5-2 (I 0.80, II 1.00, III 1.10, IV 1.20), as tabulated on steelcalculator.app and StructEd.
  • Slope factor Cs from ASCE 7-16 Figure 7.4-1, implemented as the piecewise-linear readings every independent implementation agrees on: warm roof (Ct <= 1.0), non-slippery — Cs = 1.0 to 30 degrees, then 1 - (slope - 30)/40 to 0 at 70 degrees; warm roof, slippery — Cs = 1.0 to 15 degrees, then 1 - (slope - 15)/55 to 0 at 70 degrees; cold roof (Ct > 1.0) — Cs = 1.0 to 30 degrees, then 1 - (slope - 30)/40. The two worked examples are verified against best-calculators.com's ASCE 7 snow load calculator (18.4-degree warm shingle roof -> Cs = 1.00, ps = 21.00 psf; 45-degree warm slippery metal roof, pg 40, Ce 0.9 -> Cs = 0.45, ps = 11.45 psf) and the 30-degree rule against the Chicago Building Code Cs table (<30 deg 1.00, <40 deg 0.75, <50 deg 0.50, <60 deg 0.25, >=70 deg 0.00).
  • Rain-on-snow surcharge +5 psf where pg <= 20 psf on a low-slope roof (ASCE 7-16 §7.10). This tool applies it at slopes of 5 degrees or less; secondary sources put the low-slope cutoff between 1/2:12 (about 2.4 degrees, steelcalculator.app) and 5 degrees (steelsolver.com). The standard's own test is slope W/50 or less, where W is the eave-to-ridge distance in feet — the tool states this and shows the surcharge as its own line.
  • Snow density gamma = 0.13 x pg + 14 pcf, capped at 30 pcf (ASCE 7-16 Eq. 7.7-1); balanced snow depth hb = pf / gamma (feet). Both are as stated on steelcalculator.app's reference (drift section).
  • Conversions are exact: 1 psf = 0.0478803 kPa (1 kPa = 20.8854 psf); 1 pcf = 16.0185 kg/m3; 1 lb = 0.00444822 kN; 1 US ton = 2,000 lb. Ground snow load pg is user-entered from the ASCE 7 Hazard Tool or the local building department — this tool sets no default and holds no location database.
  • Canonical examples (this tool): pg 30 psf, Terrain C partially exposed, heated, Category II, 6:12 pitch (26.6 deg), shingles — pf = 21.0 psf (1.01 kPa), minimum 20 psf, Cs = 1.00, ps = 21.0 psf, density 17.9 pcf (286.7 kg/m3), depth 1.17 ft (14.1 in, 0.36 m), total on 2,000 sq ft = 42,000 lb (21.0 US tons, 19.05 tonnes, 186.8 kN). Steep metal: pg 40, Ce 0.9, 45 deg slippery — pf = 25.2 psf (1.21 kPa), Cs = 0.45, ps = 11.45 psf (0.55 kPa). Light snow: pg 15, slope 3 deg — pf formula 10.5 psf, minimum 15.0 psf governs, rain-on-snow +5 -> design 20.0 psf (0.96 kPa). Metric twin: pg 1.44 kPa (30.07 psf) -> pf 21.05 psf (1.01 kPa), total on 185.81 m2 = 187.3 kN.
  • This tool covers balanced snow load only. Drift, unbalanced snow, sliding snow, ponding and ice dams are out of scope and are named as excluded on the page; the final design load must come from a licensed PE/SE using the adopted code edition.
  • How much snow a roof can hold (added 2026-11-07): the 20 psf typical-roof figure and the 4 ft of new snow / 2 ft of old packed snow equivalents are Maine Emergency Management Agency guidance, citing the Insurance Institute for Business and Home Safety (IBHS); the per-foot weights — fresh snow about 3 lb/ft² per foot when light and dry to about 21 lb/ft² per foot when wet and heavy, ice a little under 5 lb/ft² per inch and about 57 lb/ft² per foot — are FEMA's Snow Load Safety Guide (FEMA P-957, January 2013), summarised with the same figures at Homeowner Basics (updated October 15, 2026). All are rough planning figures, not a rating for any specific roof; the design load is the local code's ASCE ground snow load, which is what this tool calculates.
  • Depth-to-weight mode (added 2026-11-08): the same FEMA P-957 / Maine EMA rates as the snow-weight table — light 3, average about 5, wet 21, ice about 57 psf per foot; old packed snow plans at 10 psf per foot (the rate that reaches the page's 20 psf typical-roof figure at about 2 ft), with the Maine EMA range to about 20 psf per foot when wet and dense stated on the page. Cross-checked 2026-11-08 against nailthemath.com's roof snow load calculator (1 ft wet on a 1,500 sq ft footprint = 31,500 lb; 1 ft wet on a 40 x 30 ft roof = 25,200 lb — both exact at 21 psf) and onetripdiy.com's density table (fresh 3.1, settled 6.0, packed 10.8, wet 15.0 psf per foot — agrees at the light/packed end; its wet figure is the low end of the wet range, FEMA's 21 the upper end; the tool uses the FEMA figure and says so).

Figures checked on 28 November 2026 as part of the site-wide test run (3239 automated checks, all passing). See how we calculate and test.

Safety note

Never climb onto a snow-loaded roof to measure it — estimate the load from the ground, from plans, or from the hazard tool. A roof that is visibly sagging, creaking, or cracking inside under snow is a call-a-professional-now situation: keep people out from under it. Clearing snow from a roof is ladder and fall work; use a roof rake from the ground, never a metal rake near overhead power lines, and never work alone on a snowy roof.
Please note: material estimates are approximate. Always confirm product coverage with the manufacturer and buy a little extra for cuts, waste and future repairs.

What this calculator doesn't do

  • This tool gives a preliminary, educational estimate — it is NOT for construction. Roof snow load is a structural design load. The final design load for a real roof must come from a licensed professional engineer (PE/SE) using the code edition your jurisdiction has adopted, the mapped ground snow load for the exact site, and the full ASCE 7 Chapter 7 checks. Do not size rafters, trusses, beams or connections from this page.
  • This tool covers BALANCED snow load only (uniform snow on a flat or sloped roof). It does NOT cover drift loads (snow piling against parapets, at roof steps, in valleys and behind rooftop equipment), unbalanced snow on gable roofs (windward 0.3 x ps, leeward ps plus drift), sliding snow from an upper roof onto a lower one, ponding, or ice dams. On many roofs the drift or unbalanced case governs the design, not the balanced load shown here — a PE checks all of them.
  • Ground snow load pg has NO default in this tool and no location database: pg is site-specific and must never be guessed. Get it from the ASCE 7 Hazard Tool (asce7hazardtool.online) or your local building department. Using a neighbouring town's pg, a state-average pg, or a remembered figure is the single easiest way to get a wrong answer — pg ranges from 0 psf in southern Florida to 100+ psf in mountain areas.
  • The rain-on-snow surcharge (+5 psf where pg is 20 psf or less) is applied here only on low-slope roofs (5 degrees or less). ASCE 7-16 §7.10 states the surcharge for roofs with a slope of W/50 or less, where W is the eave-to-ridge distance in feet — so on a wide roof the surcharge can apply at a steeper slope than this tool's 5-degree screen. The tool shows the surcharge as its own line so you can see exactly when it applied; a PE applies the W/50 test for the actual roof.
  • The slope factor Cs is read from ASCE 7-16 Figure 7.4-1 as three piecewise-linear rules (warm slippery, warm non-slippery, cold roof — see the formula section). The standard's figure is a set of curves, so the linear readings are planning approximations of the plotted curves, accurate to about 0.02 in Cs across the range. Snow guards, parapets and obstructions that stop snow sliding mean NO slope reduction applies at all — pick the non-slippery surface if guards are fitted, and a PE checks the case.
  • The thermal factor Ct assumes the roof's heating condition stays as selected all winter. A heated building with an unheated garage wing, a cold ventilated attic over part of the roof, or a roof that is heated only intermittently needs the factors split by roof area — this tool takes one Ct for the whole roof. Continuously heated greenhouses take Ct = 0.85 in ASCE 7-16 Table 7.3-2; later editions changed that row, so a greenhouse design must confirm which edition the local code adopts.
  • Exposure factor Ce uses the terrain B/C/D table only (0.8–1.2). Windswept mountain sites above the treeline take Ce as low as 0.7 in ASCE 7 Table 7.3-1, and sites in Alaska have their own rows — neither is offered here. If your site is above the treeline or in Alaska, do not use this tool's Ce table.
  • Snow density (gamma = 0.13 x pg + 14 pcf, capped at 30 pcf) is the ASCE 7-16 Eq. 7.7-1 planning density for converting a load into a snow depth. Real snow density varies with temperature and history: fresh light snow can be 5–10 pcf, wet spring snow 20–30 pcf. The depth figure (hb = pf / gamma) is therefore a planning depth, not a measurement of the snow on your roof.
  • This tool is for the United States ASCE 7 system. Canada (NBCC), Europe (Eurocode EN 1991-1-3) and other countries use different ground snow maps, different factors and different formulas — do not apply these numbers outside the ASCE 7 jurisdictions. For the shingles and squares the load sits on, use the roofing calculator; for the insulation that sets the thermal factor, the insulation calculator.
  • The depth-to-weight mode's rates are planning figures from FEMA P-957 and Maine EMA, not measurements of your snow: real snow density varies with temperature, wind and history, and old snow varies the most — about 10 psf per foot planned, up to about 20 psf per foot when wet and dense. A depth measured on the ground is not the depth on the roof (FEMA warns the two differ: wind scours some roofs and drifts others), and a roof that has already shed or drifted snow needs a professional's judgement, not a single depth reading. Do not climb onto a snow-loaded roof to measure anything.

Roof Snow Load Calculator — frequently asked questions

How much snow can a roof hold?

About 20 pounds per square foot (0.96 kPa) of added weight for a typical US residential roof — the Maine Emergency Management Agency, citing the Insurance Institute for Business and Home Safety (IBHS), puts a typical roof at about 20 psf, which is roughly 4 ft (1.22 m) of new snow, about 2 ft (0.61 m) of old packed snow, or about 4 in (10 cm) of solid ice. Wet, heavy snow reaches 20 psf at only about 1 ft, while light, dry fresh snow takes about 6–7 ft. Roofs in snowy areas are designed for more — your local building department can tell you the design load for your area — and an older or deteriorated roof may hold less. The 20 psf figure is a rule of thumb, not a rating for your roof: the design load comes from the local code and the ASCE ground snow load for your address, which is what the tool above calculates. Stacked storms are the danger case: Maine EMA puts 2 ft of old snow plus 2 ft of new snow at as much as 60 psf (2.87 kPa), three times the typical-roof figure — the table in the worked example below gives the weight of each snow type.

How much does snow on my roof weigh?

2 ft of old packed snow weighs 20 psf (0.96 kPa) — 40,000 lb (20 US tons) on a 2,000 sq ft roof footprint — because old packed snow plans at about 10 psf per foot of depth. The weight depends on depth and type: 1 ft of fresh light snow is only 3 psf, 1 ft of average new snow about 5 psf, 1 ft of wet heavy snow 21 psf, and 1 ft of ice about 57 psf (FEMA P-957 / Maine EMA planning rates). So the same 2 ft of snow is 6 psf light and dry, 10 psf average, 42 psf wet and heavy — the type matters more than the depth. Use the depth-to-weight mode above with your measured depth and snow type, and enter your roof's design load to see the load as a percentage of what the roof was built for; when in doubt, use the wet, heavy rate.

How much does 30 cm of snow weigh on a roof?

30 cm (about 1 ft) of average new snow weighs 4.92 psf (0.24 kPa) — 5,297 lb (2.40 tonnes, 23.6 kN) on a 100 m² roof footprint. The same 30 cm as wet, heavy snow weighs 20.67 psf (0.99 kPa) — 22,248 lb (10.09 tonnes, 99.0 kN) on the same 100 m² — and as ice about 56.10 psf (2.69 kPa). Enter centimetres directly in the depth-to-weight mode: it converts to feet, applies the FEMA P-957 rate for the snow type, and returns the load in psf and kPa with the total weight in pounds, tonnes and kilonewtons.

What is the roof snow load for a 30 psf ground snow load?

21.0 psf (1.01 kPa) for a standard house — Terrain C, partially exposed (Ce = 1.0), heated (Ct = 1.0), Risk Category II (Is = 1.0): pf = 0.7 x 1.0 x 1.0 x 1.0 x 30 = 21.0 psf, above the 20 psf minimum, so 21.0 psf governs. On a 6:12 pitch (26.6 degrees) shingle roof Cs = 1.0, so the sloped design load ps is also 21.0 psf. A sheltered site (Ce = 1.2) in the same zone gives 25.2 psf; a fully exposed site in Terrain D (Ce = 0.8) gives a 16.8 psf formula value, but the 20 psf minimum governs, so the design load is 20.0 psf.

How do I calculate roof snow load?

In three steps, per ASCE 7-16 Chapter 7: (1) look up your ground snow load pg from the ASCE 7 Hazard Tool or your building department; (2) compute the flat-roof load pf = 0.7 x Ce x Ct x Is x pg, then take the larger of that and the minimum (Is x pg when pg is 20 psf or less, Is x 20 psf when pg is over 20 psf); (3) multiply by the slope factor Cs from Figure 7.4-1 to get the sloped load ps = Cs x pf, and add the 5 psf rain-on-snow surcharge where pg is 20 psf or less on a low-slope roof. The tool above does all three steps and shows each intermediate value.

What is the minimum roof snow load?

Is x pg when the ground snow load pg is 20 psf or less, and Is x 20 psf when pg is over 20 psf (ASCE 7-16 §7.3.4). For a standard Category II building (Is = 1.0) that is 15 psf in a 15 psf zone and 20 psf in a 30 psf zone. The minimum is a floor: the design flat-roof load pf is the larger of the formula value (0.7 x Ce x Ct x Is x pg) and the minimum. A sheltered site with a low exposure factor is where the minimum most often governs.

How much snow, in feet, is 21 psf on a roof?

About 1.17 ft (14.1 inches, 0.36 m) at the ASCE planning density for a 30 psf ground load: density gamma = 0.13 x 30 + 14 = 17.9 pcf, and depth = load / density = 21.0 / 17.9 = 1.17 ft. The same 21 psf would be about 2 ft of fresh light snow at 10 pcf, or about 10 inches of wet spring snow at 25 pcf — depth alone does not fix the load, because snow density varies with temperature and history. The tool reports the planning depth from the ASCE density formula, capped at 30 pcf.

What is the roof snow load in kPa?

1.01 kPa for the standard example: a ground snow load of 1.44 kPa (about 30 psf) with Ce = Ct = Is = 1.0 gives pf = 0.7 x 1.44 = 1.01 kPa. Convert with 1 psf = 0.04788 kPa (1 kPa = 20.89 psf): 21 psf is 1.01 kPa, 20 psf is 0.96 kPa, 15 psf is 0.72 kPa, and the 5 psf rain-on-snow surcharge is 0.24 kPa. Enter kPa directly in the tool — it converts to psf, runs the ASCE formulas, and returns both units.

Does rain on snow add load to a roof?

Yes — 5 psf (0.24 kPa) where the ground snow load pg is 20 psf or less, on a low-slope roof (ASCE 7-16 §7.10). Rain falling on an existing snow pack adds water weight the dry snow load does not include, and on a low-slope roof the water cannot drain before it soaks in. The tool applies the surcharge at slopes of 5 degrees or less; the standard states the test as slope W/50 or less, where W is the eave-to-ridge distance in feet, so on a wide roof it can apply at a steeper slope — a PE applies the W/50 test for the actual roof.

What is the snow load on a metal roof?

Less than on shingles at the same pitch, once the roof is steep enough for snow to slide: on a warm roof at 45 degrees, a slippery standing-seam metal roof takes Cs = 0.45 against 0.63 for shingles. At pg 40 psf with Ce = 0.9, that is pf = 25.2 psf and ps = 11.45 psf (0.55 kPa) for the metal roof, against 15.75 psf for shingles. Below 15 degrees the surface makes no difference (Cs = 1.0 for both), and with snow guards fitted the slippery reduction does not apply at all — pick the non-slippery surface.

How much does snow weigh per square foot?

It depends on depth and density: one foot of snow weighs its density in pounds per square foot — about 5–10 psf for fresh light snow, 15–20 psf for settled snow, up to 30 psf for wet spring snow. ASCE 7-16 plans with gamma = 0.13 x pg + 14 pcf (capped at 30 pcf), so in a 30 psf ground-load zone the planning density is 17.9 pcf and one foot of balanced snow weighs 17.9 psf. That is why the 21 psf design load in the worked example is about 14 inches of snow, not 21 inches.

What ground snow load do I use for my address?

The mapped 50-year ground snow load from the ASCE 7 Hazard Tool (asce7hazardtool.online) by street address, or the value your local building department has adopted from ASCE 7 Figure 7.2-1. Do not use a neighbouring town's value, a state average, a weather site's average snowfall in inches, or a remembered figure — pg is site-specific, ranges from 0 to 100+ psf across the US, and areas marked "case study" (CS) on the map need a site-specific study instead of a map value.

Do I need an engineer for roof snow load?

Yes, for any real construction or structural decision. This tool gives a preliminary balanced-load estimate for planning — a licensed PE/SE must confirm the design load with the adopted code edition, the site-specific pg, and the checks this tool does not do: drift at parapets and roof steps, unbalanced snow on gables, sliding snow from upper roofs, ponding, and ice dams. If a roof is visibly sagging, creaking, or cracking inside under snow, do not calculate — call a professional immediately and keep people out from under it.

Next step

Take the design load (psf and kPa) to your structural engineer or building department with the pg figure and its source — the hazard-tool result or the local adopted map. Then run the roofing calculator with the same roof area to check the shingles and squares the load sits on, and the insulation calculator if the thermal factor needs a second look.

Save this estimate: use the Copy link button in the results box above to share these exact inputs, or Print results for a paper copy to take to the store.