Rafter Length Calculator
A rafter is a hypotenuse with two corrections. The triangle is simple — half the building width is the run, the pitch sets the rise, and Pythagoras gives the length — but the board you cut is not the triangle: the eave overhang extends it past the wall along the same slope, and the ridge board takes half its thickness back, because the rafter stops at the ridge board's face, not at the centreline. This rafter length calculator does the whole job: enter the building width, the roof pitch (as X/12, as an angle in degrees, or as a percent grade), the overhang and the ridge board thickness, and it returns the theoretical rafter length, the cut length in feet plus fractional inches (the way a tape and a framing square read it), the tail length, the ridge deduction, the roof angle and slope factor, the hip and valley rafter length for the same roof, a birdsmouth notch check against the code limits, the next standard board length to buy, and — if you enter the roof length — the rafter count at your spacing. For the pitch itself — as x:12, degrees or percent, with the roof area and the bundle count — use the roof pitch calculator; for the shingles that cover these rafters, use the roofing calculator; for the snow load they carry, the roof snow load calculator; and for the studs and plates under them, the framing calculator.
Planning this project? Save to Pinterest to find this calculator again later.
How to use the Rafter Length Calculator
- Measure the building width first — outside of wall to outside of wall, at the eaves. The run is half that width, and every number below hangs on it: a width measured to the inside face of the wall makes every rafter short by the wall thickness times the slope factor.
- Enter the roof pitch in the form you have it. Plans and shingle specs almost always state it as rise per 12 in (6/12 means 6 in of rise per foot of run). If you only have an angle from a level or a percent grade from a drawing, switch the selector — 26.57° and 50% are the same roof as 6/12.
- Enter the eave overhang measured level from the outside of the wall. The overhang does not add inch for inch: at 6/12 a 12 in overhang adds 13.4 in of board, because the tail runs up the slope. Measure it horizontally, and let the tool do the slope conversion.
- Enter the real ridge board thickness. A 2x ridge board is 1 1/2 in thick, so 3/4 in comes off each rafter's run; a 1x board takes 3/8 in. If your ridge is an LVL at 1 3/4 in, enter that — the deduction is small, but on a short rafter it is the difference between a tight joint and a gap at the ridge.
- Read the cut length in feet and fractional inches — that is the number to mark on the board. The theoretical length (ridge centreline to wall, no overhang) is shown beside it so you can check the triangle: cut length = theoretical + tail − ridge deduction, all along the slope.
- Check the birdsmouth row before you cut. It prints the heel cut depth against the one-third and one-fourth limits for your rafter size, and the minimum rafter depth that would satisfy the one-third rule. A fail means step up a rafter size or shorten the seat cut — never cut deeper than the limit and hope the plate carries it.
- Buy the board length the tool prints, not the cut length. Lumber is sold in even feet from 8 to 24 ft, so a 16.70 ft cut needs an 18 ft board — the offcut is the ridge plumb cut and the tail cut. If the cut passes 24 ft, ask the yard about special-order lengths before you plan the job around them.
- If you entered the roof length, read the rafter count as pairs: the count per slope, doubled for the whole gable roof. Add one or two spare boards for the pattern rafter and for a board that turns out crowned the wrong way — the count is positions, not the order quantity.
- Cut one rafter first and test-fit it. Set it against the ridge board and the wall plate, check the birdsmouth sits flat and the tail lands where the fascia goes, then use that rafter as the pattern for the rest. A calculated length is exact geometry; a building is not, and the pattern rafter absorbs the difference.
- For a hip roof, read the hip rafter row. A hip runs diagonally in plan, so it is longer than a common rafter over the same run — 21.00 ft against 15.65 ft on the worked example. The hip figure is the line length before ridge deductions: cut it long, fit it, and trim to the ridge.
Rafter Length Calculator formula
Worked example
The house above, worked end to end: 28 ft wide, 6/12 pitch, 12 in overhang, 1 1/2 in ridge — theoretical rafter 15.65 ft, cut length 16 ft 8-7/16 in, hip rafter 21.00 ft, buy 18 ft boards. The overhang is worth 1.12 ft of board and the ridge board takes back less than an inch — small numbers, but they are exactly the numbers that make a rafter meet the ridge instead of falling short of it.
Common pitches (slope factor = √(1 + (pitch/12)²); hip/valley factor = √(2 + (pitch/12)²); rafter length per 10 ft of run):
| Pitch | Angle | Slope factor | Hip / valley factor | Rafter per 10 ft run |
|---|---|---|---|---|
| 3/12 | 14.0° | 1.031 | 1.436 | 10.31 ft |
| 4/12 | 18.4° | 1.054 | 1.453 | 10.54 ft |
| 5/12 | 22.6° | 1.083 | 1.474 | 10.83 ft |
| 6/12 | 26.6° | 1.118 | 1.500 | 11.18 ft |
| 7/12 | 30.3° | 1.158 | 1.530 | 11.58 ft |
| 8/12 | 33.7° | 1.202 | 1.563 | 12.02 ft |
| 9/12 | 36.9° | 1.250 | 1.601 | 12.50 ft |
| 10/12 | 39.8° | 1.302 | 1.641 | 13.02 ft |
| 12/12 | 45.0° | 1.414 | 1.732 | 14.14 ft |
Cut lengths at 6/12 (12 in overhang, 1 1/2 in ridge board — cut length and the board to buy):
| Building width | Run | Cut length | Board to buy | Hip rafter |
|---|---|---|---|---|
| 20 ft | 10 ft | 12 ft 2-3/4 in | 14 ft | 15.00 ft |
| 24 ft | 12 ft | 14 ft 5-9/16 in | 16 ft | 18.00 ft |
| 28 ft | 14 ft | 16 ft 8-7/16 in | 18 ft | 21.00 ft |
| 32 ft | 16 ft | 18 ft 11-1/4 in | 20 ft | 24.00 ft |
Metric version: 8.5 m wide building, 6/12 pitch, 30 cm overhang, 38 mm ridge board, 2x8 rafter, 89 mm seat cut. Run: 8.5 / 2 = 4.25 m. Rise: 4.25 x 0.5 = 2.125 m. Theoretical rafter: 4.25 x 1.1180 = 4.75 m. Adjusted run: 4.25 + 0.30 − 0.019 = 4.531 m. Cut length: 4.531 x 1.1180 = 5.07 m (16 ft 7-7/16 in) — buy an 18 ft board (5.49 m), since lumber is sold in even feet. Hip rafter: 4.25 x 1.5 = 6.38 m. Birdsmouth: heel = 89 x 0.5 = 44.5 mm on a 184 mm deep 2x8 — one-fourth is 46.0 mm, one-third is 61.3 mm — pass.
Measurement tips
- Measure the span outside-to-outside, not inside. A width taken to the inside face of the wall shortens every rafter by the wall thickness times the slope factor — on a 2x6 wall at 6/12 that is over 6 in of missing rafter, and the birdsmouth lands past the plate.
- Cut one rafter and test-fit it before cutting the stack. Set it on the ridge board and the wall plate, check the birdsmouth sits flat, the plumb cut meets the ridge and the tail lands where the fascia goes. The pattern rafter absorbs every small difference between the drawing and the building.
- Sight down every board before you cut it and put the crown up. A rafter with the crown down sags under load; crown up, the load straightens it. Mark the crown on the board so the whole crew cuts the same way up.
- Keep the birdsmouth shallow on steep roofs. The heel cut grows with the pitch — at 12/12 a 3 1/2 in seat cut is a 3 1/2 in heel cut, which fails the one-third rule on anything smaller than a 2x12. Steep roof, deep rafter, or a shorter seat cut: pick one before you notch.
- Order the board length, not the cut length. The offcut from an 18 ft board for a 16.70 ft rafter is the ridge plumb cut and the tail cut — it is not waste, it is the two cuts the rafter needs. Ordering exact cut lengths leaves nothing to cut.
- Space rafters 24 in on centre unless the span tables say otherwise. Sixteen-inch spacing is for heavier loads and longer spans, not a default upgrade — and it costs a third more rafters, hangers and nails for the same roof.
- Mind the heel height on low-pitch roofs. At 3/12 and 4/12 the birdsmouth heel is small, but the rafter sits low over the plate and the ceiling joists can clash with the rafter tails — check the heel height against the wall height before the walls go up, not after.
- Add the jack rafter step to your cut list on a hip roof. Each jack is one spacing shorter than the last along the slope — spacing times the slope factor, 2.24 ft at 24 in spacing on a 6/12 roof — so the whole set can be cut from one measurement instead of measured one by one.
- Do not notch a rafter anywhere but the birdsmouth. The code forbids notches in the middle third of the span and caps end notches at one-fourth of the depth — a notch cut to pass a pipe or a wire through the middle of a rafter is a structural defect, not a shortcut.
- Check the snow load before you trust a long span. A rafter that is long enough at 6/12 in a mild climate can be undersized where the ground snow load is heavy — run the same span and pitch through the roof snow load calculator and the IRC span tables together.
Common mistakes
- Forgetting the ridge board deduction. A rafter cut to the centreline length stands 3/4 in proud of the ridge board on each side — the plumb cuts do not meet, the ridge bows, and every rafter needs trimming in place. Half the ridge thickness comes off the run before the length is figured.
- Adding the overhang inch for inch. A 12 in overhang measured level is 13.4 in of board at 6/12 and 17 in at 12/12. Rafters cut with the overhang added flat come up short at the fascia by exactly that difference.
- Measuring the span inside-to-inside. The run starts at the ridge centreline and ends at the outside of the wall — an inside measurement shortens the run by the wall thickness, and the birdsmouth ends up bearing on air past the plate.
- Using the footprint multiplier for the rafter. The roofing calculator's slope factor converts area, not length — but the same number does both jobs, and the mistake is forgetting the run it multiplies. Rafter length is run times the factor; roof area is footprint times the factor. Same 1.118, different input.
- Cutting the whole stack from the calculation. Framing lumber varies, walls are rarely perfectly square, and the ridge board has its own thickness tolerance. One pattern rafter, fitted and checked, beats twelve boards cut from a number — even a correct number.
- Notching the birdsmouth too deep on a steep pitch. The heel cut is the seat length times the pitch ratio, so it doubles from 6/12 to 12/12 on the same seat cut. A 2x6 that passes at 6/12 fails at 12/12 — the tool flags it, but only if the real seat length and rafter size are entered.
- Buying the cut length instead of the board length. Lumber comes in even feet; a 16.70 ft rafter needs an 18 ft board. Ordering 16 ft boards for a 16.70 ft cut leaves a roof with no rafters at all.
- Counting rafters on one slope and ordering that many. The count per slope is half the roof — a 40 ft ridge at 24 in spacing is 21 rafters per slope and 42 in total. The tool prints both numbers; the order is the doubled one, plus spares.
- Sizing rafter depth from a length calculator. Length and span capacity are different questions: a 2x8 can be exactly the right length and still too shallow for a 16 ft span under snow load. Depth comes from the IRC span tables for your species, grade, spacing and load — never from this page.
- Treating the hip factor as a length. The hip factor multiplies the common run, not the common rafter length: at 6/12 the hip is run x 1.5, which is 21.00 ft on a 14 ft run — not 15.65 ft x 1.5. Mixing the two over-orders every hip by a third.
Factors that affect accuracy
- Building width: the dominant factor — every foot of span adds half a foot of run, times the slope factor, to each rafter. A 32 ft wide building needs rafters 2 ft 3 in longer than a 28 ft building at the same pitch, and the board size steps up with it.
- Roof pitch: steeper roofs need longer rafters for the same span — the slope factor runs from 1.031 at 3/12 to 1.414 at 12/12 — and the heel cut grows with it too, so pitch moves the birdsmouth check as well as the length.
- Eave overhang: every inch of overhang adds more than an inch of board (overhang x slope factor), and on a hip roof it adds more still (overhang x hip factor). A 24 in overhang at 6/12 is 2.24 ft of rafter, not 2 ft.
- Ridge board thickness: a small deduction with a visible effect — half of a 1 1/2 in ridge board is 0.84 in of slope length at 6/12. It matters most on short rafters, where it is a larger share of the length, and it is the difference between a plumb cut that meets the ridge and one that stands proud.
- Rafter size: depth does not change the cut length, but it decides the birdsmouth check — a deeper rafter tolerates a deeper heel cut. On a steep pitch the choice of 2x8 over 2x6 is often what makes the notch legal.
- Seat cut length: the heel cut is the seat times the pitch ratio, so a longer seat (a wider wall plate) deepens the notch. A 2x6 wall with a 5 1/2 in seat cut needs a deeper rafter than a 2x4 wall at the same pitch.
- Roof length and spacing: the rafter count is set by the ridge length divided by the spacing, plus one — 16 in spacing needs half as many rafters again as 24 in spacing on the same roof, which is the real cost of the tighter spacing.
- Hip or valley: a hip rafter covers the diagonal, so it runs the hip factor (1.5 at 6/12) against the common run instead of the slope factor (1.118) — about a third longer than the common rafter over the same span, before any overhang.
- Lumber lengths: boards come in even feet, so the order length steps in 2 ft jumps while the cut length moves smoothly. A cut of 16.70 ft and a cut of 17.90 ft both buy 18 ft boards; a cut of 18.05 ft buys 20 ft.
- Waste and spares: the count is positions, not the order. One spare board covers the pattern rafter and one crowned the wrong way; on a long roof, add a board or two for the jacks, which are cut from the same stock in descending lengths.
Sources & assumptions
- Method — the rafter triangle plus the two framing corrections, per onlycalculators' rafter length calculator (published 2026-06-24: adjusted run = run + overhang − half ridge thickness, length = adjusted run × slope factor, slope factor = √(rise² + 144) / 12) and CalculatorZilo's rafter calculator (run = span / 2, rafter = √(run² + rise²), rafter count = floor(roof length × 12 / 24) + 1 per slope at 24 in OC, next whole-foot board) and SkilledHub's rafter length calculator (buy the next even lumber length — a 14.53 ft rafter takes a 16 ft board; jack common difference = spacing × slope factor). This tool follows onlycalculators' adjusted-run method and rounds the board up to the next even foot, as SkilledHub does.
- Slope factors — √(1 + (pitch / 12)²), verified 2026-11-12 against MaterialGuides' roof pitch factor chart (6/12 = 1.118, hip factor 1.5), StepwiseCalc's roof pitch calculator (6/12 slope factor 1.1180, hip factor 1.5000, common rafter 15.65 ft on a 14 ft run) and Plan7Architect's roof pitch calculator (same table, 6/12 1.118 / 1.500, 12/12 1.414 / 1.732). The same multipliers are on this site's roofing calculator.
- Hip/valley factor — √(2 + (pitch / 12)²) per foot of common run, for a regular hip (equal pitches meeting at 90° in plan), per MaterialGuides, RoofGenius' hip roof calculator (hip = run × √(pitch² + 288) / 12; 6/12 hip 1.5, 12/12 1.7321) and Roof Observations' hip and valley factor guide (factor = √((rise/run)² + 2); 6/12 = 1.5). Hip lengths are line lengths before ridge deductions.
- Ridge deduction — half the ridge board thickness off the horizontal run, because the rafter ends at the ridge board's face, not the centreline: onlycalculators (0.75 in for a 2x board), CalculatorZilo (half the thickness comes off the run), SkilledHub (deduct half the ridge board thickness measured level) and CalculateRoofPitch all agree. Overhang adds along the slope (overhang × slope factor) — onlycalculators and CalculatorZilo agree; on a hip it adds overhang × hip factor (SkilledHub).
- Birdsmouth limits — the dedicated rafter tools apply a one-third rule to the heel cut, citing IRC R802.7.1: onlycalculators (d_min = 3 × heel cut; 2x6 max heel 1.83 in, 2x8 2.42 in), 907 Heating & Plumbing and CalcExp (1/3 the general residential limit). The IRC text itself (R802.7.1, quoted by Fine Homebuilding and JLC) limits notches at the ends of members to one-fourth of the depth — so this tool flags heel cuts over one-fourth as a caution and over one-third as a fail, and prints the minimum rafter depth (3 × heel). Heel cut = seat cut × pitch / 12. Actual lumber depths are the American Lumber Standard (PS 20): 2x4 3.5 in, 2x6 5.5 in, 2x8 7.25 in, 2x10 9.25 in, 2x12 11.25 in.
- Board lengths — standard stocked lumber 8–24 ft in 2-ft steps; buy the next even length at or above the cut (SkilledHub). Rafter depth and span capacity are NOT sized here: they come from the IRC span tables R802.4.1(1) through R802.4.1(8) (SkilledHub) for species, grade, spacing, snow load and roof load.
- Canonical examples (this tool): span 28 ft, pitch 6/12, overhang 12 in, ridge 1.5 in, rafter 2x8, seat 3.5 in — run 14 ft, rise 7 ft, slope factor 1.1180, angle 26.57°, theoretical 15.65 ft (15 ft 7-13/16 in), adjusted run 14.9375 ft, cut 16.70 ft (16 ft 8-7/16 in), tail 1.12 ft (1 ft 1-7/16 in), ridge deduction 0.84 in, hip factor 1.500, hip 21.00 ft (22.50 ft with overhang), heel 1.75 in vs D/4 1.81 in and D/3 2.42 in — pass, remaining depth 5.50 in, next board 18 ft. Metric twin (8.5 m span, 30 cm overhang, 38 mm ridge, 89 mm seat): theoretical 4.75 m, cut 5.07 m (16 ft 7-7/16 in), next board 18 ft (5.49 m), heel 44.5 mm vs D/4 46.0 mm — pass. 12/12 case (24 ft span): theoretical 16.97 ft, cut 18.30 ft, next board 20 ft, hip 20.78 ft. 4/12 case (30 ft span, 24 in overhang): theoretical 15.81 ft, cut 17.85 ft, next board 18 ft, heel 1.17 in on a 2x6 — pass. Birdsmouth caution (6/12, 2x6, 3.5 in seat): heel 1.75 in, over D/4 1.38 in, under D/3 1.83 in. Birdsmouth fail (12/12, 2x6, 3.5 in seat): heel 3.50 in, over D/3 1.83 in, minimum depth 10.50 in (2x12). Count (40 ft roof at 24 in OC): 21 per slope, 42 total.
Figures checked on 28 November 2026 as part of the site-wide test run (3239 automated checks, all passing). See how we calculate and test.
Safety note
What this calculator doesn't do
- This tool sizes length, not the member. How deep a rafter must be — and how far it may span — depends on species, grade, spacing, snow load and roof load, from the IRC span tables (R802.4.1(1) through R802.4.1(8)) or a structural engineer. A 2x6 that is long enough on paper can still be too shallow for its span; this tool never sizes rafter depth, and the birdsmouth check only tests the notch against the depth you enter.
- It assumes a gable roof of one pitch with level eaves. The hip and valley figures assume a regular hip — both roof planes at the same pitch, meeting at 90° in plan. Unequal pitches, octagonal roofs and roofs with a structural ridge beam need a drawing or framing software, not a single-pitch formula.
- The cut length is the line length along the top edge of the rafter, from the ridge face to the tail cut. Plumb and level cuts, the birdsmouth notch and the fascia board are layout, not extra length — cut one rafter, test-fit it against the ridge and the wall plate, and use it as the pattern for the rest.
- The ridge deduction assumes the rafter meets the face of an ordinary ridge board. A structural ridge beam, a ridge board thicker than the 2x or LVL sizes in the list, or a ridge set below the rafter tops changes the detail — measure the actual deduction on the pattern rafter.
- The birdsmouth check compares the heel cut against two limits: one-third of the rafter depth (the rule the dedicated rafter tools apply, citing IRC R802.7.1) and one-fourth (the IRC text for notches at the ends of members). Some inspectors enforce the stricter quarter — the tool flags it as a caution rather than passing it silently.
- Board lengths are the standard stocked sizes, 8–24 ft in 2-ft steps. A cut length over 24 ft needs a special-order length, a spliced rafter or a different roof design — ask your lumberyard before you order, and never splice a rafter at mid-span without an engineer's detail.
Rafter Length Calculator — frequently asked questions
How long should my rafters be?
For a 28 ft wide building at a 6/12 pitch with a 12 in overhang and a 1 1/2 in ridge board, each common rafter is cut 16 ft 8-7/16 in long (16.70 ft) — buy 18 ft boards. The theoretical rafter is 15.65 ft; the overhang adds 1.12 ft along the slope and the ridge board takes 0.84 in back. Enter your own span, pitch, overhang and ridge thickness in the tool: cut length = (run + overhang − ridge / 2) × slope factor.
How do you calculate rafter length?
Work the triangle, then apply the two corrections. Run = building width / 2; rise = run × pitch / 12; slope factor = √(1 + (pitch / 12)²). The theoretical rafter is run × slope factor. Then add the overhang and subtract half the ridge board thickness from the run before multiplying: cut length = (run + overhang − ridge / 2) × slope factor. A 28 ft building at 6/12 with a 12 in overhang and a 1 1/2 in ridge works out to (14 + 1 − 0.0625) × 1.1180 = 16.70 ft.
How much do I subtract for the ridge board?
Half the ridge board thickness, taken off the horizontal run before the slope factor is applied — not off the finished rafter length. A 2x ridge board is 1 1/2 in thick, so 3/4 in comes off the run, which is 0.84 in of slope length at 6/12. A 1x board (3/4 in) takes 3/8 in off the run; an LVL ridge at 1 3/4 in takes 7/8 in. The rafter stops at the face of the ridge board, not at its centreline. In metric, a 38 mm ridge board takes 19 mm off the run (21 mm of slope length at 6/12); a 19 mm board takes 9.5 mm.
What is the rafter length for a 6/12 pitch?
Multiply the run (half the building width) by the 6/12 slope factor, 1.1180 — that is the theoretical rafter, ridge centreline to wall. A 14 ft run gives 15.65 ft; with a 12 in overhang and a 1 1/2 in ridge board the cut length is 16.70 ft (16 ft 8-7/16 in). Per 10 ft of run the rafter is 11.18 ft — per 3 m of run it is 3.35 m. The full pitch table on this page lists 3/12 through 12/12 with the hip factor beside each.
What size lumber do I need for rafters?
For length, buy the next even board size at or above the cut length: a 16.70 ft cut needs an 18 ft board; boards are stocked 8–24 ft in 2-ft steps. For depth — whether a 2x6, 2x8 or 2x10 is strong enough — use the IRC span tables (R802.4.1) for your species, grade, spacing, snow load and roof load, or ask an engineer. This tool sizes the length only; it never sizes the member.
How deep can a birdsmouth cut be?
The heel cut must stay within one-third of the rafter depth — the rule the dedicated rafter tools apply, citing IRC R802.7.1. The IRC text itself limits notches at the ends of members to one-fourth of the depth, and some inspectors enforce that stricter figure. This tool flags both: a heel over one-fourth is a caution, over one-third is a fail. On a 2x8 at 6/12 with a 3 1/2 in seat cut the heel is 1.75 in — inside both limits (1.81 in and 2.42 in). At 12/12 the same seat cut is a 3 1/2 in heel, which fails on anything smaller than a 2x12.
How long is a hip rafter?
Multiply the common run by the hip/valley factor, √(2 + (pitch / 12)²) — 1.500 at 6/12, 1.732 at 12/12. On a 28 ft wide building at 6/12 the run is 14 ft, so the hip rafter is 14 × 1.5 = 21.00 ft (22.50 ft with a 12 in overhang), against 15.65 ft for the common rafter. The factor multiplies the run, not the common rafter length — and it assumes a regular hip, with both planes at the same pitch meeting at 90° in plan.
How many rafters do I need?
Count positions along the ridge: floor(roof length / spacing) + 1 per slope, then double it for both slopes of a gable roof. A 40 ft ridge at 24 in on centre is 21 rafters per slope and 42 in total; at 16 in on centre it is 31 per slope and 62 total. Enter the roof length in the tool and it prints both numbers — then add one or two spare boards for the pattern rafter and for a board that turns out crowned the wrong way.
How do I calculate rafter length in metres?
The same formula, in metres: run = span / 2, slope factor = √(1 + (pitch / 12)²), cut length = (run + overhang − ridge / 2) × slope factor. For an 8.5 m wide building at 6/12 with a 30 cm overhang and a 38 mm ridge board: run 4.25 m, theoretical rafter 4.75 m, cut length 5.07 m. Buy 18 ft boards (5.49 m), since lumber is sold in even feet — a 5.07 m cut does not fit a 16 ft (4.88 m) board. The birdsmouth heel is 44.5 mm on a 184 mm deep 2x8, inside both limits.
How do I measure roof pitch?
Hold a level 12 in out from the roof surface (or from the top of a rafter) and measure straight down from the level to the roof — that drop, in inches, is the pitch: a 6 in drop over 12 in of run is a 6/12 pitch, a 26.57° angle, a 50% grade. In metric, hold the level 300 mm out and measure the drop in millimetres — a 150 mm drop over 300 mm is the same 6/12 roof. Measure on the rafter itself where you can, not on the shingles, and take the reading in two or three places — old roofs sag and the pitch varies. This tool accepts the pitch as X/12, as degrees, or as percent grade.
Next step
Cut one rafter first and test-fit it against the ridge board and the wall plate — check the birdsmouth sits flat and the tail lands where the fascia goes — then use it as the pattern for the rest. Then check the snow load those rafters will carry with the roof snow load calculator, and price the shingles over them with the roofing calculator.
Save this estimate: use the Copy link button in the results box above to share these exact inputs, or Print results for a paper copy to take to the store.